A citation-based method for searching scientific literature

Takashi D Y Kozai, Kasey Catt, Xia Li, Zhannetta V Gugel, Valur T Olafsson, Alberto L Vazquez, X Tracy Cui. Biomaterials 2015
Times Cited: 111







List of co-cited articles
1044 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


The upregulation of specific interleukin (IL) receptor antagonists and paradoxical enhancement of neuronal apoptosis due to electrode induced strain and brain micromotion.
Lohitash Karumbaiah, Sharon E Norman, Nithish B Rajan, Sanjay Anand, Tarun Saxena, Martha Betancur, Radhika Patkar, Ravi V Bellamkonda. Biomaterials 2012
61
26

Brain micromotion around implants in the rodent somatosensory cortex.
Aaron Gilletti, Jit Muthuswamy. J Neural Eng 2006
143
16

Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex.
Daryl R Kipke, Rio J Vetter, Justin C Williams, Jamille F Hetke. IEEE Trans Neural Syst Rehabil Eng 2003
197
16

The roles of blood-derived macrophages and resident microglia in the neuroinflammatory response to implanted intracortical microelectrodes.
Madhumitha Ravikumar, Smrithi Sunil, James Black, Deborah S Barkauskas, Alex Y Haung, Robert H Miller, Stephen M Selkirk, Jeffrey R Capadona. Biomaterials 2014
53
30


Intracortical microstimulation of human somatosensory cortex.
Sharlene N Flesher, Jennifer L Collinger, Stephen T Foldes, Jeffrey M Weiss, John E Downey, Elizabeth C Tyler-Kabara, Sliman J Bensmaia, Andrew B Schwartz, Michael L Boninger, Robert A Gaunt. Sci Transl Med 2016
260
16


Cerebral astrocyte response to micromachined silicon implants.
J N Turner, W Shain, D H Szarowski, M Andersen, S Martins, M Isaacson, H Craighead. Exp Neurol 1999
346
15


Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.
J P Harris, J R Capadona, R H Miller, B C Healy, K Shanmuganathan, S J Rowan, C Weder, D J Tyler. J Neural Eng 2011
105
15


Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes.
Chong Xie, Jia Liu, Tian-Ming Fu, Xiaochuan Dai, Wei Zhou, Charles M Lieber. Nat Mater 2015
168
15

Using a common average reference to improve cortical neuron recordings from microelectrode arrays.
Kip A Ludwig, Rachel M Miriani, Nicholas B Langhals, Michael D Joseph, David J Anderson, Daryl R Kipke. J Neurophysiol 2009
171
14

Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes.
Kip A Ludwig, Nicholas B Langhals, Mike D Joseph, Sarah M Richardson-Burns, Jeffrey L Hendricks, Daryl R Kipke. J Neural Eng 2011
126
14

Thiol-ene/acrylate substrates for softening intracortical electrodes.
Taylor Ware, Dustin Simon, Clive Liu, Tabassum Musa, Srikanth Vasudevan, Andrew Sloan, Edward W Keefer, Robert L Rennaker, Walter Voit. J Biomed Mater Res B Appl Biomater 2014
62
22

In Vivo Electrochemical Analysis of a PEDOT/MWCNT Neural Electrode Coating.
Nicolas A Alba, Zhanhong J Du, Kasey A Catt, Takashi D Y Kozai, X Tracy Cui. Biosensors (Basel) 2015
51
27


Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex.
D J Edell, V V Toi, V M McNeil, L D Clark. IEEE Trans Biomed Eng 1992
264
14

A comparison of the tissue response to chronically implanted Parylene-C-coated and uncoated planar silicon microelectrode arrays in rat cortex.
Brent D Winslow, Michael B Christensen, Wen-Kuo Yang, Florian Solzbacher, Patrick A Tresco. Biomaterials 2010
102
14

Flexible polyimide-based intracortical electrode arrays with bioactive capability.
P J Rousche, D S Pellinen, D P Pivin, J C Williams, R J Vetter, D R Kipke. IEEE Trans Biomed Eng 2001
285
13

The origin of extracellular fields and currents--EEG, ECoG, LFP and spikes.
György Buzsáki, Costas A Anastassiou, Christof Koch. Nat Rev Neurosci 2012
13

Chronic, multisite, multielectrode recordings in macaque monkeys.
Miguel A L Nicolelis, Dragan Dimitrov, Jose M Carmena, Roy Crist, Gary Lehew, Jerald D Kralik, Steven P Wise. Proc Natl Acad Sci U S A 2003
410
13

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.
Rio J Vetter, Justin C Williams, Jamille F Hetke, Elizabeth A Nunamaker, Daryl R Kipke. IEEE Trans Biomed Eng 2004
258
13


Curcumin-releasing mechanically adaptive intracortical implants improve the proximal neuronal density and blood-brain barrier stability.
Kelsey A Potter, Mehdi Jorfi, Kyle T Householder, E Johan Foster, Christoph Weder, Jeffrey R Capadona. Acta Biomater 2014
67
19


Melatonin improves quality and longevity of chronic neural recording.
Asiyeh Golabchi, Bingchen Wu, Xia Li, Diane L Carlisle, Takashi D Y Kozai, Robert M Friedlander, Xinyan Tracy Cui. Biomaterials 2018
34
38

Minocycline increases quality and longevity of chronic neural recordings.
R L Rennaker, J Miller, H Tang, D A Wilson. J Neural Eng 2007
74
16

A carbon-fiber electrode array for long-term neural recording.
Grigori Guitchounts, Jeffrey E Markowitz, William A Liberti, Timothy J Gardner. J Neural Eng 2013
106
12

Advanced neurotechnologies for chronic neural interfaces: new horizons and clinical opportunities.
Daryl R Kipke, William Shain, György Buzsáki, E Fetz, Jaimie M Henderson, Jamille F Hetke, Gerwin Schalk. J Neurosci 2008
157
12


Syringe-injectable electronics.
Jia Liu, Tian-Ming Fu, Zengguang Cheng, Guosong Hong, Tao Zhou, Lihua Jin, Madhavi Duvvuri, Zhe Jiang, Peter Kruskal, Chong Xie,[...]. Nat Nanotechnol 2015
271
12

Neuronal ensemble control of prosthetic devices by a human with tetraplegia.
Leigh R Hochberg, Mijail D Serruya, Gerhard M Friehs, Jon A Mukand, Maryam Saleh, Abraham H Caplan, Almut Branner, David Chen, Richard D Penn, John P Donoghue. Nature 2006
12


The relationship between glial cell mechanosensitivity and foreign body reactions in the central nervous system.
Pouria Moshayedi, Gilbert Ng, Jessica C F Kwok, Giles S H Yeo, Clare E Bryant, James W Fawcett, Kristian Franze, Jochen Guck. Biomaterials 2014
173
12

Foreign body reaction to biomaterials.
James M Anderson, Analiz Rodriguez, David T Chang. Semin Immunol 2008
12

Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration.
A Bolu Ajiboye, Francis R Willett, Daniel R Young, William D Memberg, Brian A Murphy, Jonathan P Miller, Benjamin L Walter, Jennifer A Sweet, Harry A Hoyen, Michael W Keith,[...]. Lancet 2017
275
12

Neural stimulation and recording with bidirectional, soft carbon nanotube fiber microelectrodes.
Flavia Vitale, Samantha R Summerson, Behnaam Aazhang, Caleb Kemere, Matteo Pasquali. ACS Nano 2015
111
12

Electrical stimulation of excitable tissue: design of efficacious and safe protocols.
Daniel R Merrill, Marom Bikson, John G R Jefferys. J Neurosci Methods 2005
849
12

Targeting CD14 on blood derived cells improves intracortical microelectrode performance.
Hillary W Bedell, John K Hermann, Madhumitha Ravikumar, Shushen Lin, Ashley Rein, Xujia Li, Emily Molinich, Patrick D Smith, Stephen M Selkirk, Robert H Miller,[...]. Biomaterials 2018
30
40

Nanofabricated Ultraflexible Electrode Arrays for High-Density Intracortical Recording.
Xiaoling Wei, Lan Luan, Zhengtuo Zhao, Xue Li, Hanlin Zhu, Ojas Potnis, Chong Xie. Adv Sci (Weinh) 2018
46
26

Carbon nanotube nanoreservior for controlled release of anti-inflammatory dexamethasone.
Xiliang Luo, Christopher Matranga, Susheng Tan, Nicolas Alba, Xinyan T Cui. Biomaterials 2011
117
11

Evaluation of poly(3,4-ethylenedioxythiophene)/carbon nanotube neural electrode coatings for stimulation in the dorsal root ganglion.
Christi L Kolarcik, Kasey Catt, Erika Rost, Ingrid N Albrecht, Dennis Bourbeau, Zhanhong Du, Takashi D Y Kozai, Xiliang Luo, Douglas J Weber, X Tracy Cui. J Neural Eng 2015
57
19


In vivo effects of L1 coating on inflammation and neuronal health at the electrode-tissue interface in rat spinal cord and dorsal root ganglion.
C L Kolarcik, D Bourbeau, E Azemi, E Rost, L Zhang, C F Lagenaur, D J Weber, X T Cui. Acta Biomater 2012
44
25

Dexamethasone treatment reduces astroglia responses to inserted neuroprosthetic devices in rat neocortex.
L Spataro, J Dilgen, S Retterer, A J Spence, M Isaacson, J N Turner, W Shain. Exp Neurol 2005
131
11

Compliant intracortical implants reduce strains and strain rates in brain tissue in vivo.
Arati Sridharan, Jessica K Nguyen, Jeffrey R Capadona, Jit Muthuswamy. J Neural Eng 2015
46
23

Data-driven model comparing the effects of glial scarring and interface interactions on chronic neural recordings in non-human primates.
Karlo A Malaga, Karen E Schroeder, Paras R Patel, Zachary T Irwin, David E Thompson, J Nicole Bentley, Scott F Lempka, Cynthia A Chestek, Parag G Patil. J Neural Eng 2016
38
28

Chronic response of adult rat brain tissue to implants anchored to the skull.
Young-Tae Kim, Robert W Hitchcock, Michael J Bridge, Patrick A Tresco. Biomaterials 2004
132
11

In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes.
J P Harris, A E Hess, S J Rowan, C Weder, C A Zorman, D J Tyler, J R Capadona. J Neural Eng 2011
87
12


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.