A citation-based method for searching scientific literature

Hyunjung Lee, Ravi V Bellamkonda, Wei Sun, Marc E Levenston. J Neural Eng 2005
Times Cited: 122







List of co-cited articles
1240 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


Response of brain tissue to chronically implanted neural electrodes.
Vadim S Polikov, Patrick A Tresco, William M Reichert. J Neurosci Methods 2005
896
60

A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex.
Jeyakumar Subbaroyan, David C Martin, Daryl R Kipke. J Neural Eng 2005
177
47


Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces.
Takashi D Yoshida Kozai, Nicholas B Langhals, Paras R Patel, Xiaopei Deng, Huanan Zhang, Karen L Smith, Joerg Lahann, Nicholas A Kotov, Daryl R Kipke. Nat Mater 2012
329
42

Brain micromotion around implants in the rodent somatosensory cortex.
Aaron Gilletti, Jit Muthuswamy. J Neural Eng 2006
143
37

Brain responses to micro-machined silicon devices.
D H Szarowski, M D Andersen, S Retterer, A J Spence, M Isaacson, H G Craighead, J N Turner, W Shain. Brain Res 2003
464
33

The impact of chronic blood-brain barrier breach on intracortical electrode function.
Tarun Saxena, Lohitash Karumbaiah, Eric A Gaupp, Radhika Patkar, Ketki Patil, Martha Betancur, Garrett B Stanley, Ravi V Bellamkonda. Biomaterials 2013
157
33

Neural probe design for reduced tissue encapsulation in CNS.
John P Seymour, Daryl R Kipke. Biomaterials 2007
241
31

Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration.
George C McConnell, Howard D Rees, Allan I Levey, Claire-Anne Gutekunst, Robert E Gross, Ravi V Bellamkonda. J Neural Eng 2009
257
30


Flexible polyimide-based intracortical electrode arrays with bioactive capability.
P J Rousche, D S Pellinen, D P Pivin, J C Williams, R J Vetter, D R Kipke. IEEE Trans Biomed Eng 2001
285
28

Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.
James C Barrese, Naveen Rao, Kaivon Paroo, Corey Triebwasser, Carlos Vargas-Irwin, Lachlan Franquemont, John P Donoghue. J Neural Eng 2013
269
28

Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants.
Abhishek Prasad, Qing-Shan Xue, Viswanath Sankar, Toshikazu Nishida, Gerry Shaw, Wolfgang J Streit, Justin C Sanchez. J Neural Eng 2012
167
27

Neuronal ensemble control of prosthetic devices by a human with tetraplegia.
Leigh R Hochberg, Mijail D Serruya, Gerhard M Friehs, Jon A Mukand, Maryam Saleh, Abraham H Caplan, Almut Branner, David Chen, Richard D Penn, John P Donoghue. Nature 2006
26

Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex.
D J Edell, V V Toi, V M McNeil, L D Clark. IEEE Trans Biomed Eng 1992
264
26

Toward a comparison of microelectrodes for acute and chronic recordings.
Matthew P Ward, Pooja Rajdev, Casey Ellison, Pedro P Irazoqui. Brain Res 2009
171
26

Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion.
C S Bjornsson, S J Oh, Y A Al-Kofahi, Y J Lim, K L Smith, J N Turner, S De, B Roysam, W Shain, S J Kim. J Neural Eng 2006
184
25

Cerebral astrocyte response to micromachined silicon implants.
J N Turner, W Shain, D H Szarowski, M Andersen, S Martins, M Isaacson, H Craighead. Exp Neurol 1999
346
24

Neural stimulation and recording electrodes.
Stuart F Cogan. Annu Rev Biomed Eng 2008
835
24

Multifunctional fibers for simultaneous optical, electrical and chemical interrogation of neural circuits in vivo.
Andres Canales, Xiaoting Jia, Ulrich P Froriep, Ryan A Koppes, Christina M Tringides, Jennifer Selvidge, Chi Lu, Chong Hou, Lei Wei, Yoel Fink,[...]. Nat Biotechnol 2015
246
24

Relationship between intracortical electrode design and chronic recording function.
Lohitash Karumbaiah, Tarun Saxena, David Carlson, Ketki Patil, Radhika Patkar, Eric A Gaupp, Martha Betancur, Garrett B Stanley, Lawrence Carin, Ravi V Bellamkonda. Biomaterials 2013
130
23


Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants.
Justin C Williams, Joseph A Hippensteel, John Dilgen, William Shain, Daryl R Kipke. J Neural Eng 2007
220
22


Reach and grasp by people with tetraplegia using a neurally controlled robotic arm.
Leigh R Hochberg, Daniel Bacher, Beata Jarosiewicz, Nicolas Y Masse, John D Simeral, Joern Vogel, Sami Haddadin, Jie Liu, Sydney S Cash, Patrick van der Smagt,[...]. Nature 2012
22

Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex.
J C Williams, R L Rennaker, D R Kipke. Brain Res Brain Res Protoc 1999
227
21


The upregulation of specific interleukin (IL) receptor antagonists and paradoxical enhancement of neuronal apoptosis due to electrode induced strain and brain micromotion.
Lohitash Karumbaiah, Sharon E Norman, Nithish B Rajan, Sanjay Anand, Tarun Saxena, Martha Betancur, Radhika Patkar, Ravi V Bellamkonda. Biomaterials 2012
61
34

3D Parylene sheath neural probe for chronic recordings.
B J Kim, J T W Kuo, S A Hara, C D Lee, L Yu, C A Gutierrez, T Q Hoang, V Pikov, E Meng. J Neural Eng 2013
77
27

Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.
T D Y Kozai, T C Marzullo, F Hooi, N B Langhals, A K Majewska, E B Brown, D R Kipke. J Neural Eng 2010
105
20


Mechanically-compliant intracortical implants reduce the neuroinflammatory response.
Jessica K Nguyen, Daniel J Park, John L Skousen, Allison E Hess-Dunning, Dustin J Tyler, Stuart J Rowan, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2014
118
20

Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording.
Takashi D Y Kozai, Kasey Catt, Xia Li, Zhannetta V Gugel, Valur T Olafsson, Alberto L Vazquez, X Tracy Cui. Biomaterials 2015
111
20

Brain tissue responses to neural implants impact signal sensitivity and intervention strategies.
Takashi D Y Kozai, Andrea S Jaquins-Gerstl, Alberto L Vazquez, Adrian C Michael, X Tracy Cui. ACS Chem Neurosci 2015
229
20


Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes.
Takashi D Y Kozai, Zhannetta Gugel, Xia Li, Peter J Gilgunn, Rakesh Khilwani, O Burak Ozdoganlar, Gary K Fedder, Douglas J Weber, X Tracy Cui. Biomaterials 2014
104
19

Biomaterials. Electronic dura mater for long-term multimodal neural interfaces.
Ivan R Minev, Pavel Musienko, Arthur Hirsch, Quentin Barraud, Nikolaus Wenger, Eduardo Martin Moraud, Jérôme Gandar, Marco Capogrosso, Tomislav Milekovic, Léonie Asboth,[...]. Science 2015
401
19

Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes.
Chong Xie, Jia Liu, Tian-Ming Fu, Xiaochuan Dai, Wei Zhou, Charles M Lieber. Nat Mater 2015
168
19

Implant size and fixation mode strongly influence tissue reactions in the CNS.
Jonas Thelin, Henrik Jörntell, Elia Psouni, Martin Garwicz, Jens Schouenborg, Nils Danielsen, Cecilia Eriksson Linsmeier. PLoS One 2011
101
18

In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes.
Takashi D Yoshida Kozai, Alberto L Vazquez, Cassandra L Weaver, Seong-Gi Kim, X Tracy Cui. J Neural Eng 2012
111
18

A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array.
P K Campbell, K E Jones, R J Huber, K W Horch, R A Normann. IEEE Trans Biomed Eng 1991
274
18

Ultraflexible nanoelectronic probes form reliable, glial scar-free neural integration.
Lan Luan, Xiaoling Wei, Zhengtuo Zhao, Jennifer J Siegel, Ojas Potnis, Catherine A Tuppen, Shengqing Lin, Shams Kazmi, Robert A Fowler, Stewart Holloway,[...]. Sci Adv 2017
187
18


Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics.
Dae-Hyeong Kim, Jonathan Viventi, Jason J Amsden, Jianliang Xiao, Leif Vigeland, Yun-Soung Kim, Justin A Blanco, Bruce Panilaitis, Eric S Frechette, Diego Contreras,[...]. Nat Mater 2010
617
17

In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes.
J P Harris, A E Hess, S J Rowan, C Weder, C A Zorman, D J Tyler, J R Capadona. J Neural Eng 2011
87
19

Progress towards biocompatible intracortical microelectrodes for neural interfacing applications.
Mehdi Jorfi, John L Skousen, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2015
164
17

Chronic, multisite, multielectrode recordings in macaque monkeys.
Miguel A L Nicolelis, Dragan Dimitrov, Jose M Carmena, Roy Crist, Gary Lehew, Jerald D Kralik, Steven P Wise. Proc Natl Acad Sci U S A 2003
410
16

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.
Rio J Vetter, Justin C Williams, Jamille F Hetke, Elizabeth A Nunamaker, Daryl R Kipke. IEEE Trans Biomed Eng 2004
258
16

Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.
J P Harris, J R Capadona, R H Miller, B C Healy, K Shanmuganathan, S J Rowan, C Weder, D J Tyler. J Neural Eng 2011
105
16

Injectable, cellular-scale optoelectronics with applications for wireless optogenetics.
Tae-il Kim, Jordan G McCall, Yei Hwan Jung, Xian Huang, Edward R Siuda, Yuhang Li, Jizhou Song, Young Min Song, Hsuan An Pao, Rak-Hwan Kim,[...]. Science 2013
518
16


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.