A citation-based method for searching scientific literature

C S Bjornsson, S J Oh, Y A Al-Kofahi, Y J Lim, K L Smith, J N Turner, S De, B Roysam, W Shain, S J Kim. J Neural Eng 2006
Times Cited: 177







List of co-cited articles
1155 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity



Response of brain tissue to chronically implanted neural electrodes.
Vadim S Polikov, Patrick A Tresco, William M Reichert. J Neurosci Methods 2005
865
43

Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces.
Takashi D Yoshida Kozai, Nicholas B Langhals, Paras R Patel, Xiaopei Deng, Huanan Zhang, Karen L Smith, Joerg Lahann, Nicholas A Kotov, Daryl R Kipke. Nat Mater 2012
306
39

Brain responses to micro-machined silicon devices.
D H Szarowski, M D Andersen, S Retterer, A J Spence, M Isaacson, H G Craighead, J N Turner, W Shain. Brain Res 2003
453
38

In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes.
Takashi D Yoshida Kozai, Alberto L Vazquez, Cassandra L Weaver, Seong-Gi Kim, X Tracy Cui. J Neural Eng 2012
104
37

Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.
James C Barrese, Naveen Rao, Kaivon Paroo, Corey Triebwasser, Carlos Vargas-Irwin, Lachlan Franquemont, John P Donoghue. J Neural Eng 2013
253
36

The impact of chronic blood-brain barrier breach on intracortical electrode function.
Tarun Saxena, Lohitash Karumbaiah, Eric A Gaupp, Radhika Patkar, Ketki Patil, Martha Betancur, Garrett B Stanley, Ravi V Bellamkonda. Biomaterials 2013
150
35

Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex.
D J Edell, V V Toi, V M McNeil, L D Clark. IEEE Trans Biomed Eng 1992
260
34

Neural probe design for reduced tissue encapsulation in CNS.
John P Seymour, Daryl R Kipke. Biomaterials 2007
231
33

Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.
T D Y Kozai, T C Marzullo, F Hooi, N B Langhals, A K Majewska, E B Brown, D R Kipke. J Neural Eng 2010
102
31


Brain tissue responses to neural implants impact signal sensitivity and intervention strategies.
Takashi D Y Kozai, Andrea S Jaquins-Gerstl, Alberto L Vazquez, Adrian C Michael, X Tracy Cui. ACS Chem Neurosci 2015
217
31

Cerebral astrocyte response to micromachined silicon implants.
J N Turner, W Shain, D H Szarowski, M Andersen, S Martins, M Isaacson, H Craighead. Exp Neurol 1999
343
30

Reach and grasp by people with tetraplegia using a neurally controlled robotic arm.
Leigh R Hochberg, Daniel Bacher, Beata Jarosiewicz, Nicolas Y Masse, John D Simeral, Joern Vogel, Sami Haddadin, Jie Liu, Sydney S Cash, Patrick van der Smagt,[...]. Nature 2012
958
29


Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration.
George C McConnell, Howard D Rees, Allan I Levey, Claire-Anne Gutekunst, Robert E Gross, Ravi V Bellamkonda. J Neural Eng 2009
248
28

Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants.
Abhishek Prasad, Qing-Shan Xue, Viswanath Sankar, Toshikazu Nishida, Gerry Shaw, Wolfgang J Streit, Justin C Sanchez. J Neural Eng 2012
162
26

Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes.
Takashi D Y Kozai, Zhannetta Gugel, Xia Li, Peter J Gilgunn, Rakesh Khilwani, O Burak Ozdoganlar, Gary K Fedder, Douglas J Weber, X Tracy Cui. Biomaterials 2014
101
25

A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex.
Jeyakumar Subbaroyan, David C Martin, Daryl R Kipke. J Neural Eng 2005
168
25

High-performance neuroprosthetic control by an individual with tetraplegia.
Jennifer L Collinger, Brian Wodlinger, John E Downey, Wei Wang, Elizabeth C Tyler-Kabara, Douglas J Weber, Angus J C McMorland, Meel Velliste, Michael L Boninger, Andrew B Schwartz. Lancet 2013
699
24

Relationship between intracortical electrode design and chronic recording function.
Lohitash Karumbaiah, Tarun Saxena, David Carlson, Ketki Patil, Radhika Patkar, Eric A Gaupp, Martha Betancur, Garrett B Stanley, Lawrence Carin, Ravi V Bellamkonda. Biomaterials 2013
125
24

Progress towards biocompatible intracortical microelectrodes for neural interfacing applications.
Mehdi Jorfi, John L Skousen, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2015
152
24

Effects of caspase-1 knockout on chronic neural recording quality and longevity: insight into cellular and molecular mechanisms of the reactive tissue response.
Takashi D Y Kozai, Xia Li, Lance M Bodily, Ellen M Caparosa, Georgios A Zenonos, Diane L Carlisle, Robert M Friedlander, X Tracy Cui. Biomaterials 2014
80
28

Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants.
Justin C Williams, Joseph A Hippensteel, John Dilgen, William Shain, Daryl R Kipke. J Neural Eng 2007
215
23

Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex.
J C Williams, R L Rennaker, D R Kipke. Brain Res Brain Res Protoc 1999
223
23


Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording.
Takashi D Y Kozai, Kasey Catt, Xia Li, Zhannetta V Gugel, Valur T Olafsson, Alberto L Vazquez, X Tracy Cui. Biomaterials 2015
102
22

Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.
J P Harris, J R Capadona, R H Miller, B C Healy, K Shanmuganathan, S J Rowan, C Weder, D J Tyler. J Neural Eng 2011
100
21


Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants.
Abhishek Prasad, Qing-Shan Xue, Robert Dieme, Viswanath Sankar, Roxanne C Mayrand, Toshikazu Nishida, Wolfgang J Streit, Justin C Sanchez. Front Neuroeng 2014
102
21

Mechanically-compliant intracortical implants reduce the neuroinflammatory response.
Jessica K Nguyen, Daniel J Park, John L Skousen, Allison E Hess-Dunning, Dustin J Tyler, Stuart J Rowan, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2014
111
21

Large-scale recording of neuronal ensembles.
György Buzsáki. Nat Neurosci 2004
868
21

Toward a comparison of microelectrodes for acute and chronic recordings.
Matthew P Ward, Pooja Rajdev, Casey Ellison, Pedro P Irazoqui. Brain Res 2009
167
21


In vivo penetration mechanics and mechanical properties of mouse brain tissue at micrometer scales.
Andrew A Sharp, Alicia M Ortega, Diego Restrepo, Douglas Curran-Everett, Ken Gall. IEEE Trans Biomed Eng 2009
64
29

Neuronal ensemble control of prosthetic devices by a human with tetraplegia.
Leigh R Hochberg, Mijail D Serruya, Gerhard M Friehs, Jon A Mukand, Maryam Saleh, Abraham H Caplan, Almut Branner, David Chen, Richard D Penn, John P Donoghue. Nature 2006
18

Brain micromotion around implants in the rodent somatosensory cortex.
Aaron Gilletti, Jit Muthuswamy. J Neural Eng 2006
133
18

BBB leakage, astrogliosis, and tissue loss correlate with silicon microelectrode array recording performance.
Nicholas F Nolta, Michael B Christensen, Paul D Crane, John L Skousen, Patrick A Tresco. Biomaterials 2015
89
20

Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.
Paras R Patel, Kyounghwan Na, Huanan Zhang, Takashi D Y Kozai, Nicholas A Kotov, Euisik Yoon, Cynthia A Chestek. J Neural Eng 2015
72
25


Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex.
Cynthia A Chestek, Vikash Gilja, Paul Nuyujukian, Justin D Foster, Joline M Fan, Matthew T Kaufman, Mark M Churchland, Zuley Rivera-Alvidrez, John P Cunningham, Stephen I Ryu,[...]. J Neural Eng 2011
176
17

The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes.
Kelsey A Potter, Amy C Buck, Wade K Self, Megan E Callanan, Smrithi Sunil, Jeffrey R Capadona. Biomaterials 2013
76
22

Dexamethasone treatment reduces astroglia responses to inserted neuroprosthetic devices in rat neocortex.
L Spataro, J Dilgen, S Retterer, A J Spence, M Isaacson, J N Turner, W Shain. Exp Neurol 2005
128
17


Glial responses to implanted electrodes in the brain.
Joseph W Salatino, Kip A Ludwig, Takashi D Y Kozai, Erin K Purcell. Nat Biomed Eng 2017
140
17

Controlling cellular reactive responses around neural prosthetic devices using peripheral and local intervention strategies.
William Shain, Leah Spataro, Jonathan Dilgen, Kraig Haverstick, Scott Retterer, Michael Isaacson, Mark Saltzman, James N Turner. IEEE Trans Neural Syst Rehabil Eng 2003
144
16


Biomechanical analysis of silicon microelectrode-induced strain in the brain.
Hyunjung Lee, Ravi V Bellamkonda, Wei Sun, Marc E Levenston. J Neural Eng 2005
117
16

In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes.
J P Harris, A E Hess, S J Rowan, C Weder, C A Zorman, D J Tyler, J R Capadona. J Neural Eng 2011
83
19

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.
Rio J Vetter, Justin C Williams, Jamille F Hetke, Elizabeth A Nunamaker, Daryl R Kipke. IEEE Trans Biomed Eng 2004
254
16


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.