A citation-based method for searching scientific literature

J Gotman, L Y Wang. Electroencephalogr Clin Neurophysiol 1991
Times Cited: 69







List of co-cited articles
199 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity



State dependent spike detection: validation.
J Gotman, L Y Wang. Electroencephalogr Clin Neurophysiol 1992
47
59

Automated interictal EEG spike detection using artificial neural networks.
A J Gabor, M Seyal. Electroencephalogr Clin Neurophysiol 1992
77
40



Automatic EEG spike detection: what should the computer imitate?
W R Webber, B Litt, R P Lesser, R S Fisher, I Bankman. Electroencephalogr Clin Neurophysiol 1993
62
27


Spike detection II: automatic, perception-based detection and clustering.
S B Wilson, C A Turner, R G Emerson, M L Scheuer. Clin Neurophysiol 1999
62
27

A multistage system to detect epileptiform activity in the EEG.
A A Dingle, R D Jones, G J Carroll, W R Fright. IEEE Trans Biomed Eng 1993
59
27

Automatic recognition of inter-ictal epileptic activity in prolonged EEG recordings.
J Gotman, J R Ives, P Gloor. Electroencephalogr Clin Neurophysiol 1979
85
20

Expert system approach to detection of epileptiform activity in the EEG.
B L Davey, W R Fright, G J Carroll, R D Jones. Med Biol Eng Comput 1989
35
40

Spike detection: a review and comparison of algorithms.
Scott B Wilson, Ronald Emerson. Clin Neurophysiol 2002
112
20

Assessment of a computer program to detect epileptiform spikes.
W E Hostetler, H J Doller, R W Homan. Electroencephalogr Clin Neurophysiol 1992
43
30

Spike detection. I. Correlation and reliability of human experts.
S B Wilson, R N Harner, F H Duffy, B R Tharp, M R Nuwer, M R Sperling. Electroencephalogr Clin Neurophysiol 1996
57
22

Automatic recognition of epileptic seizures in the EEG.
J Gotman. Electroencephalogr Clin Neurophysiol 1982
287
18


Comparison of traditional reading of the EEG and automatic recognition of interictal epileptic activity.
J Gotman, P Gloor, N Schaul. Electroencephalogr Clin Neurophysiol 1978
40
30

Spike detection based on a pattern recognition approach using a microcomputer.
P Guedes de Oliveira, C Queiroz, F Lopes da Silva. Electroencephalogr Clin Neurophysiol 1983
34
35



Detection of spikes with artificial neural networks using raw EEG.
O Ozdamar, T Kalayci. Comput Biomed Res 1998
23
39

A new approach to spike detection using a combination of inverse and matched filter techniques.
G Pfurtscheller, G Fischer. Electroencephalogr Clin Neurophysiol 1978
20
45

Evaluation of a computerized system for recognition of epileptic activity during long-term EEG recording.
T Pietilä, S Vapaakoski, U Nousiainen, A Värri, H Frey, V Häkkinen, Y Neuvo. Electroencephalogr Clin Neurophysiol 1994
20
40

A multichannel signal processor for the detection of epileptogenic sharp transients in the EEG.
J R Glover, P Y Ktonas, N Raghavan, J M Uruñuela, S S Velamuri, E L Reilly. IEEE Trans Biomed Eng 1986
17
47

An automated system for epileptogenic focus localization in the electroencephalogram.
B Ramabhadran, J D Frost, J R Glover, P Y Ktonas. J Clin Neurophysiol 1999
16
50

Pattern recognition of the electroencephalogram by artificial neural networks.
G Jandó, R M Siegel, Z Horváth, G Buzsáki. Electroencephalogr Clin Neurophysiol 1993
47
14

Automatic detection of spike-and-wave bursts in ambulatory EEG recordings.
D J Koffler, J Gotman. Electroencephalogr Clin Neurophysiol 1985
28
25

Indications of nonlinear deterministic and finite-dimensional structures in time series of brain electrical activity: dependence on recording region and brain state.
R G Andrzejak, K Lehnertz, F Mormann, C Rieke, P David, C E Elger. Phys Rev E Stat Nonlin Soft Matter Phys 2001
385
10

Fast wavelet transformation of EEG.
S J Schiff, A Aldroubi, M Unser, S Sato. Electroencephalogr Clin Neurophysiol 1994
97
8

Detection of epileptic events in electroencephalograms using wavelet analysis.
C E D'Attellis, S I Isaacson, R O Sirne. Ann Biomed Eng 1997
24
25

Automatic seizure detection: improvements and evaluation.
J Gotman. Electroencephalogr Clin Neurophysiol 1990
140
8


Wavelet analysis of EEG for three-dimensional mapping of epileptic events.
L Senhadji, J L Dillenseger, F Wendling, C Rocha, A Kinie. Ann Biomed Eng 1995
28
21


Simultaneous spike detection and topographic classification in pediatric surface EEGs.
M Feucht, K Hoffmann, K Steinberger, H Witte, F Benninger, M Arnold, A Doering. Neuroreport 1997
10
60

Detection of seizure activity in EEG by an artificial neural network: a preliminary study.
N Pradhan, P K Sadasivan, G R Arunodaya. Comput Biomed Res 1996
39
15


Automatic detection of epileptiform events in EEG by a three-stage procedure based on artificial neural networks.
Nurettin Acir, Ibrahim Oztura, Mehmet Kuntalp, Bariş Baklan, Cüneyt Güzeliş. IEEE Trans Biomed Eng 2005
49
12

EEG spike detection with a Kohonen feature map.
C Kurth, F Gilliam, B J Steinhoff. Ann Biomed Eng 2000
16
37

Computerized seizure detection of complex partial seizures.
A M Murro, D W King, J R Smith, B B Gallagher, H F Flanigin, K Meador. Electroencephalogr Clin Neurophysiol 1991
48
10

Automatic detection of seizures and spikes.
J Gotman. J Clin Neurophysiol 1999
102
7

Real-time detection of epileptiform activity in the EEG: a blinded clinical trial.
M A Black, R D Jones, G J Carroll, A A Dingle, I M Donaldson, P J Parkin. Clin Electroencephalogr 2000
18
27

Automatic computer analysis of transients in EEG.
R Sankar, J Natour. Comput Biol Med 1992
14
35


A neural-network-based detection of epilepsy.
Vivek Prakash Nigam, Daniel Graupe. Neurol Res 2004
78
7

A multistage, multimethod approach for automatic detection and classification of epileptiform EEG.
He Sheng Liu, Tong Zhang, Fu Sheng Yang. IEEE Trans Biomed Eng 2002
33
15

A comparison of algorithms for detection of spikes in the electroencephalogram.
Clement C C Pang, Adrian R M Upton, Glenn Shine, Markad V Kamath. IEEE Trans Biomed Eng 2003
35
14

Interictal spike detection using the Walsh transform.
Malek Adjouadi, Danmary Sanchez, Mercedes Cabrerizo, Melvin Ayala, Prasanna Jayakar, Ilker Yaylali, Armando Barreto. IEEE Trans Biomed Eng 2004
37
13

SADE3: an effective system for automated detection of epileptiform events in long-term EEG based on context information.
Fernanda I M Argoud, Fernando M De Azevedo, José Marino Neto, Eugênio Grillo. Med Biol Eng Comput 2006
16
31



Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.