A citation-based method for searching scientific literature

Roy Biran, Dave C Martin, Patrick A Tresco. J Biomed Mater Res A 2007
Times Cited: 203







List of co-cited articles
905 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


Response of brain tissue to chronically implanted neural electrodes.
Vadim S Polikov, Patrick A Tresco, William M Reichert. J Neurosci Methods 2005
926
49


Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.
James C Barrese, Naveen Rao, Kaivon Paroo, Corey Triebwasser, Carlos Vargas-Irwin, Lachlan Franquemont, John P Donoghue. J Neural Eng 2013
283
33

Brain responses to micro-machined silicon devices.
D H Szarowski, M D Andersen, S Retterer, A J Spence, M Isaacson, H G Craighead, J N Turner, W Shain. Brain Res 2003
472
31

Cerebral astrocyte response to micromachined silicon implants.
J N Turner, W Shain, D H Szarowski, M Andersen, S Martins, M Isaacson, H Craighead. Exp Neurol 1999
352
28

Implant size and fixation mode strongly influence tissue reactions in the CNS.
Jonas Thelin, Henrik Jörntell, Elia Psouni, Martin Garwicz, Jens Schouenborg, Nils Danielsen, Cecilia Eriksson Linsmeier. PLoS One 2011
104
28

Brain tissue responses to neural implants impact signal sensitivity and intervention strategies.
Takashi D Y Kozai, Andrea S Jaquins-Gerstl, Alberto L Vazquez, Adrian C Michael, X Tracy Cui. ACS Chem Neurosci 2015
240
28

Neural probe design for reduced tissue encapsulation in CNS.
John P Seymour, Daryl R Kipke. Biomaterials 2007
247
28

Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration.
George C McConnell, Howard D Rees, Allan I Levey, Claire-Anne Gutekunst, Robert E Gross, Ravi V Bellamkonda. J Neural Eng 2009
268
25

The impact of chronic blood-brain barrier breach on intracortical electrode function.
Tarun Saxena, Lohitash Karumbaiah, Eric A Gaupp, Radhika Patkar, Ketki Patil, Martha Betancur, Garrett B Stanley, Ravi V Bellamkonda. Biomaterials 2013
159
23

Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces.
Takashi D Yoshida Kozai, Nicholas B Langhals, Paras R Patel, Xiaopei Deng, Huanan Zhang, Karen L Smith, Joerg Lahann, Nicholas A Kotov, Daryl R Kipke. Nat Mater 2012
344
23

Reach and grasp by people with tetraplegia using a neurally controlled robotic arm.
Leigh R Hochberg, Daniel Bacher, Beata Jarosiewicz, Nicolas Y Masse, John D Simeral, Joern Vogel, Sami Haddadin, Jie Liu, Sydney S Cash, Patrick van der Smagt,[...]. Nature 2012
23

Neuronal ensemble control of prosthetic devices by a human with tetraplegia.
Leigh R Hochberg, Mijail D Serruya, Gerhard M Friehs, Jon A Mukand, Maryam Saleh, Abraham H Caplan, Almut Branner, David Chen, Richard D Penn, John P Donoghue. Nature 2006
22

BBB leakage, astrogliosis, and tissue loss correlate with silicon microelectrode array recording performance.
Nicholas F Nolta, Michael B Christensen, Paul D Crane, John L Skousen, Patrick A Tresco. Biomaterials 2015
95
23

High-performance neuroprosthetic control by an individual with tetraplegia.
Jennifer L Collinger, Brian Wodlinger, John E Downey, Wei Wang, Elizabeth C Tyler-Kabara, Douglas J Weber, Angus J C McMorland, Meel Velliste, Michael L Boninger, Andrew B Schwartz. Lancet 2013
774
21

Relationship between intracortical electrode design and chronic recording function.
Lohitash Karumbaiah, Tarun Saxena, David Carlson, Ketki Patil, Radhika Patkar, Eric A Gaupp, Martha Betancur, Garrett B Stanley, Lawrence Carin, Ravi V Bellamkonda. Biomaterials 2013
135
20

Chronic response of adult rat brain tissue to implants anchored to the skull.
Young-Tae Kim, Robert W Hitchcock, Michael J Bridge, Patrick A Tresco. Biomaterials 2004
136
20

Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.
T D Y Kozai, T C Marzullo, F Hooi, N B Langhals, A K Majewska, E B Brown, D R Kipke. J Neural Eng 2010
108
20

Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants.
Abhishek Prasad, Qing-Shan Xue, Viswanath Sankar, Toshikazu Nishida, Gerry Shaw, Wolfgang J Streit, Justin C Sanchez. J Neural Eng 2012
171
19

Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex.
D J Edell, V V Toi, V M McNeil, L D Clark. IEEE Trans Biomed Eng 1992
266
19

In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes.
Takashi D Yoshida Kozai, Alberto L Vazquez, Cassandra L Weaver, Seong-Gi Kim, X Tracy Cui. J Neural Eng 2012
117
19

Brain micromotion around implants in the rodent somatosensory cortex.
Aaron Gilletti, Jit Muthuswamy. J Neural Eng 2006
144
18

Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion.
C S Bjornsson, S J Oh, Y A Al-Kofahi, Y J Lim, K L Smith, J N Turner, S De, B Roysam, W Shain, S J Kim. J Neural Eng 2006
188
18

Progress towards biocompatible intracortical microelectrodes for neural interfacing applications.
Mehdi Jorfi, John L Skousen, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2015
169
17

Neural stimulation and recording electrodes.
Stuart F Cogan. Annu Rev Biomed Eng 2008
881
17

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.
Rio J Vetter, Justin C Williams, Jamille F Hetke, Elizabeth A Nunamaker, Daryl R Kipke. IEEE Trans Biomed Eng 2004
276
16

Mechanically-compliant intracortical implants reduce the neuroinflammatory response.
Jessica K Nguyen, Daniel J Park, John L Skousen, Allison E Hess-Dunning, Dustin J Tyler, Stuart J Rowan, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2014
119
16

Toward a comparison of microelectrodes for acute and chronic recordings.
Matthew P Ward, Pooja Rajdev, Casey Ellison, Pedro P Irazoqui. Brain Res 2009
172
16

Ultraflexible nanoelectronic probes form reliable, glial scar-free neural integration.
Lan Luan, Xiaoling Wei, Zhengtuo Zhao, Jennifer J Siegel, Ojas Potnis, Catherine A Tuppen, Shengqing Lin, Shams Kazmi, Robert A Fowler, Stewart Holloway,[...]. Sci Adv 2017
193
16


Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex.
J C Williams, R L Rennaker, D R Kipke. Brain Res Brain Res Protoc 1999
233
15

Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex.
Cynthia A Chestek, Vikash Gilja, Paul Nuyujukian, Justin D Foster, Joline M Fan, Matthew T Kaufman, Mark M Churchland, Zuley Rivera-Alvidrez, John P Cunningham, Stephen I Ryu,[...]. J Neural Eng 2011
187
14

A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array.
P K Campbell, K E Jones, R J Huber, K W Horch, R A Normann. IEEE Trans Biomed Eng 1991
285
14

Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes.
Takashi D Y Kozai, Zhannetta Gugel, Xia Li, Peter J Gilgunn, Rakesh Khilwani, O Burak Ozdoganlar, Gary K Fedder, Douglas J Weber, X Tracy Cui. Biomaterials 2014
107
14

Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants.
Abhishek Prasad, Qing-Shan Xue, Robert Dieme, Viswanath Sankar, Roxanne C Mayrand, Toshikazu Nishida, Wolfgang J Streit, Justin C Sanchez. Front Neuroeng 2014
110
13


Brain-controlled interfaces: movement restoration with neural prosthetics.
Andrew B Schwartz, X Tracy Cui, Douglas J Weber, Daniel W Moran. Neuron 2006
364
13


Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex.
Selim Suner, Matthew R Fellows, Carlos Vargas-Irwin, Gordon Kenji Nakata, John P Donoghue. IEEE Trans Neural Syst Rehabil Eng 2005
258
13

Flexible polyimide-based intracortical electrode arrays with bioactive capability.
P J Rousche, D S Pellinen, D P Pivin, J C Williams, R J Vetter, D R Kipke. IEEE Trans Biomed Eng 2001
290
13

Effects of caspase-1 knockout on chronic neural recording quality and longevity: insight into cellular and molecular mechanisms of the reactive tissue response.
Takashi D Y Kozai, Xia Li, Lance M Bodily, Ellen M Caparosa, Georgios A Zenonos, Diane L Carlisle, Robert M Friedlander, X Tracy Cui. Biomaterials 2014
85
15



Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.
Paras R Patel, Kyounghwan Na, Huanan Zhang, Takashi D Y Kozai, Nicholas A Kotov, Euisik Yoon, Cynthia A Chestek. J Neural Eng 2015
80
16

Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants.
Justin C Williams, Joseph A Hippensteel, John Dilgen, William Shain, Daryl R Kipke. J Neural Eng 2007
227
12


A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex.
Jeyakumar Subbaroyan, David C Martin, Daryl R Kipke. J Neural Eng 2005
184
12

Chronic tissue response to untethered microelectrode implants in the rat brain and spinal cord.
Ali Ersen, Stella Elkabes, David S Freedman, Mesut Sahin. J Neural Eng 2015
28
42


Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording.
Takashi D Y Kozai, Kasey Catt, Xia Li, Zhannetta V Gugel, Valur T Olafsson, Alberto L Vazquez, X Tracy Cui. Biomaterials 2015
114
12


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.