A citation-based method for searching scientific literature

Brent D Winslow, Michael B Christensen, Wen-Kuo Yang, Florian Solzbacher, Patrick A Tresco. Biomaterials 2010
Times Cited: 104







List of co-cited articles
978 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity



Response of brain tissue to chronically implanted neural electrodes.
Vadim S Polikov, Patrick A Tresco, William M Reichert. J Neurosci Methods 2005
935
56

Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration.
George C McConnell, Howard D Rees, Allan I Levey, Claire-Anne Gutekunst, Robert E Gross, Ravi V Bellamkonda. J Neural Eng 2009
272
47

Brain responses to micro-machined silicon devices.
D H Szarowski, M D Andersen, S Retterer, A J Spence, M Isaacson, H G Craighead, J N Turner, W Shain. Brain Res 2003
477
41



The impact of chronic blood-brain barrier breach on intracortical electrode function.
Tarun Saxena, Lohitash Karumbaiah, Eric A Gaupp, Radhika Patkar, Ketki Patil, Martha Betancur, Garrett B Stanley, Ravi V Bellamkonda. Biomaterials 2013
159
34

Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.
James C Barrese, Naveen Rao, Kaivon Paroo, Corey Triebwasser, Carlos Vargas-Irwin, Lachlan Franquemont, John P Donoghue. J Neural Eng 2013
285
31

Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants.
Abhishek Prasad, Qing-Shan Xue, Viswanath Sankar, Toshikazu Nishida, Gerry Shaw, Wolfgang J Streit, Justin C Sanchez. J Neural Eng 2012
172
30


Reach and grasp by people with tetraplegia using a neurally controlled robotic arm.
Leigh R Hochberg, Daniel Bacher, Beata Jarosiewicz, Nicolas Y Masse, John D Simeral, Joern Vogel, Sami Haddadin, Jie Liu, Sydney S Cash, Patrick van der Smagt,[...]. Nature 2012
28

Cerebral astrocyte response to micromachined silicon implants.
J N Turner, W Shain, D H Szarowski, M Andersen, S Martins, M Isaacson, H Craighead. Exp Neurol 1999
354
27

Neural probe design for reduced tissue encapsulation in CNS.
John P Seymour, Daryl R Kipke. Biomaterials 2007
247
27

Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces.
Takashi D Yoshida Kozai, Nicholas B Langhals, Paras R Patel, Xiaopei Deng, Huanan Zhang, Karen L Smith, Joerg Lahann, Nicholas A Kotov, Daryl R Kipke. Nat Mater 2012
350
27

Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants.
Justin C Williams, Joseph A Hippensteel, John Dilgen, William Shain, Daryl R Kipke. J Neural Eng 2007
229
26


Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays.
John L Skousen, Sr Mary Elizabeth Merriam, Onnap Srivannavit, Gaytri Perlin, Kensall D Wise, Patrick A Tresco. Prog Brain Res 2011
72
34


Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion.
C S Bjornsson, S J Oh, Y A Al-Kofahi, Y J Lim, K L Smith, J N Turner, S De, B Roysam, W Shain, S J Kim. J Neural Eng 2006
190
23

Toward a comparison of microelectrodes for acute and chronic recordings.
Matthew P Ward, Pooja Rajdev, Casey Ellison, Pedro P Irazoqui. Brain Res 2009
172
23

Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.
J P Harris, J R Capadona, R H Miller, B C Healy, K Shanmuganathan, S J Rowan, C Weder, D J Tyler. J Neural Eng 2011
108
23

Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex.
D J Edell, V V Toi, V M McNeil, L D Clark. IEEE Trans Biomed Eng 1992
268
22

Large-scale recording of neuronal ensembles.
György Buzsáki. Nat Neurosci 2004
928
22

Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.
T D Y Kozai, T C Marzullo, F Hooi, N B Langhals, A K Majewska, E B Brown, D R Kipke. J Neural Eng 2010
108
22



Chronic response of adult rat brain tissue to implants anchored to the skull.
Young-Tae Kim, Robert W Hitchcock, Michael J Bridge, Patrick A Tresco. Biomaterials 2004
136
22

The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes.
Kelsey A Potter, Amy C Buck, Wade K Self, Megan E Callanan, Smrithi Sunil, Jeffrey R Capadona. Biomaterials 2013
84
26

In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes.
Takashi D Yoshida Kozai, Alberto L Vazquez, Cassandra L Weaver, Seong-Gi Kim, X Tracy Cui. J Neural Eng 2012
120
21

In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes.
J P Harris, A E Hess, S J Rowan, C Weder, C A Zorman, D J Tyler, J R Capadona. J Neural Eng 2011
90
22

Neuronal ensemble control of prosthetic devices by a human with tetraplegia.
Leigh R Hochberg, Mijail D Serruya, Gerhard M Friehs, Jon A Mukand, Maryam Saleh, Abraham H Caplan, Almut Branner, David Chen, Richard D Penn, John P Donoghue. Nature 2006
20

Brain tissue responses to neural implants impact signal sensitivity and intervention strategies.
Takashi D Y Kozai, Andrea S Jaquins-Gerstl, Alberto L Vazquez, Adrian C Michael, X Tracy Cui. ACS Chem Neurosci 2015
246
20

Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording.
Takashi D Y Kozai, Kasey Catt, Xia Li, Zhannetta V Gugel, Valur T Olafsson, Alberto L Vazquez, X Tracy Cui. Biomaterials 2015
114
20

Progress towards biocompatible intracortical microelectrodes for neural interfacing applications.
Mehdi Jorfi, John L Skousen, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2015
171
20

A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex.
Jeyakumar Subbaroyan, David C Martin, Daryl R Kipke. J Neural Eng 2005
185
19

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.
Rio J Vetter, Justin C Williams, Jamille F Hetke, Elizabeth A Nunamaker, Daryl R Kipke. IEEE Trans Biomed Eng 2004
276
19


Relationship between intracortical electrode design and chronic recording function.
Lohitash Karumbaiah, Tarun Saxena, David Carlson, Ketki Patil, Radhika Patkar, Eric A Gaupp, Martha Betancur, Garrett B Stanley, Lawrence Carin, Ravi V Bellamkonda. Biomaterials 2013
136
19

Effects of caspase-1 knockout on chronic neural recording quality and longevity: insight into cellular and molecular mechanisms of the reactive tissue response.
Takashi D Y Kozai, Xia Li, Lance M Bodily, Ellen M Caparosa, Georgios A Zenonos, Diane L Carlisle, Robert M Friedlander, X Tracy Cui. Biomaterials 2014
86
22

Dexamethasone treatment reduces astroglia responses to inserted neuroprosthetic devices in rat neocortex.
L Spataro, J Dilgen, S Retterer, A J Spence, M Isaacson, J N Turner, W Shain. Exp Neurol 2005
135
18

Minocycline increases quality and longevity of chronic neural recordings.
R L Rennaker, J Miller, H Tang, D A Wilson. J Neural Eng 2007
77
23

Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes.
Takashi D Y Kozai, Zhannetta Gugel, Xia Li, Peter J Gilgunn, Rakesh Khilwani, O Burak Ozdoganlar, Gary K Fedder, Douglas J Weber, X Tracy Cui. Biomaterials 2014
108
18

Cortical neural prosthetics.
Andrew B Schwartz. Annu Rev Neurosci 2004
294
17

High-performance neuroprosthetic control by an individual with tetraplegia.
Jennifer L Collinger, Brian Wodlinger, John E Downey, Wei Wang, Elizabeth C Tyler-Kabara, Douglas J Weber, Angus J C McMorland, Meel Velliste, Michael L Boninger, Andrew B Schwartz. Lancet 2013
780
17

Bioimpedance modeling to monitor astrocytic response to chronically implanted electrodes.
G C McConnell, R J Butera, R V Bellamkonda. J Neural Eng 2009
68
23

Neural stimulation and recording electrodes.
Stuart F Cogan. Annu Rev Biomed Eng 2008
898
16

Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants.
Abhishek Prasad, Qing-Shan Xue, Robert Dieme, Viswanath Sankar, Roxanne C Mayrand, Toshikazu Nishida, Wolfgang J Streit, Justin C Sanchez. Front Neuroeng 2014
110
16

Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex.
J C Williams, R L Rennaker, D R Kipke. Brain Res Brain Res Protoc 1999
234
15

Controlled release of anti-inflammatory agent alpha-MSH from neural implants.
Yinghui Zhong, Ravi V Bellamkonda. J Control Release 2005
82
18



Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.