A citation-based method for searching scientific literature

J P Harris, A E Hess, S J Rowan, C Weder, C A Zorman, D J Tyler, J R Capadona. J Neural Eng 2011
Times Cited: 90







List of co-cited articles
883 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


Response of brain tissue to chronically implanted neural electrodes.
Vadim S Polikov, Patrick A Tresco, William M Reichert. J Neurosci Methods 2005
926
53


Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.
J P Harris, J R Capadona, R H Miller, B C Healy, K Shanmuganathan, S J Rowan, C Weder, D J Tyler. J Neural Eng 2011
106
45

A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex.
Jeyakumar Subbaroyan, David C Martin, Daryl R Kipke. J Neural Eng 2005
184
38

Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces.
Takashi D Yoshida Kozai, Nicholas B Langhals, Paras R Patel, Xiaopei Deng, Huanan Zhang, Karen L Smith, Joerg Lahann, Nicholas A Kotov, Daryl R Kipke. Nat Mater 2012
344
36

Mechanically-compliant intracortical implants reduce the neuroinflammatory response.
Jessica K Nguyen, Daniel J Park, John L Skousen, Allison E Hess-Dunning, Dustin J Tyler, Stuart J Rowan, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2014
119
36

Stimuli-responsive polymer nanocomposites inspired by the sea cucumber dermis.
Jeffrey R Capadona, Kadhiravan Shanmuganathan, Dustin J Tyler, Stuart J Rowan, Christoph Weder. Science 2008
370
34


Brain responses to micro-machined silicon devices.
D H Szarowski, M D Andersen, S Retterer, A J Spence, M Isaacson, H G Craighead, J N Turner, W Shain. Brain Res 2003
472
30

Flexible polyimide-based intracortical electrode arrays with bioactive capability.
P J Rousche, D S Pellinen, D P Pivin, J C Williams, R J Vetter, D R Kipke. IEEE Trans Biomed Eng 2001
290
30

Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration.
George C McConnell, Howard D Rees, Allan I Levey, Claire-Anne Gutekunst, Robert E Gross, Ravi V Bellamkonda. J Neural Eng 2009
268
28

Neural probe design for reduced tissue encapsulation in CNS.
John P Seymour, Daryl R Kipke. Biomaterials 2007
247
28

The impact of chronic blood-brain barrier breach on intracortical electrode function.
Tarun Saxena, Lohitash Karumbaiah, Eric A Gaupp, Radhika Patkar, Ketki Patil, Martha Betancur, Garrett B Stanley, Ravi V Bellamkonda. Biomaterials 2013
159
28

Thiol-ene/acrylate substrates for softening intracortical electrodes.
Taylor Ware, Dustin Simon, Clive Liu, Tabassum Musa, Srikanth Vasudevan, Andrew Sloan, Edward W Keefer, Robert L Rennaker, Walter Voit. J Biomed Mater Res B Appl Biomater 2014
63
41

Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.
James C Barrese, Naveen Rao, Kaivon Paroo, Corey Triebwasser, Carlos Vargas-Irwin, Lachlan Franquemont, John P Donoghue. J Neural Eng 2013
283
28

Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants.
Abhishek Prasad, Qing-Shan Xue, Viswanath Sankar, Toshikazu Nishida, Gerry Shaw, Wolfgang J Streit, Justin C Sanchez. J Neural Eng 2012
171
26

Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion.
C S Bjornsson, S J Oh, Y A Al-Kofahi, Y J Lim, K L Smith, J N Turner, S De, B Roysam, W Shain, S J Kim. J Neural Eng 2006
188
25

Neural stimulation and recording electrodes.
Stuart F Cogan. Annu Rev Biomed Eng 2008
881
25



Reach and grasp by people with tetraplegia using a neurally controlled robotic arm.
Leigh R Hochberg, Daniel Bacher, Beata Jarosiewicz, Nicolas Y Masse, John D Simeral, Joern Vogel, Sami Haddadin, Jie Liu, Sydney S Cash, Patrick van der Smagt,[...]. Nature 2012
24

Toward a comparison of microelectrodes for acute and chronic recordings.
Matthew P Ward, Pooja Rajdev, Casey Ellison, Pedro P Irazoqui. Brain Res 2009
172
23

A comparison of the tissue response to chronically implanted Parylene-C-coated and uncoated planar silicon microelectrode arrays in rat cortex.
Brent D Winslow, Michael B Christensen, Wen-Kuo Yang, Florian Solzbacher, Patrick A Tresco. Biomaterials 2010
103
23

Brain tissue responses to neural implants impact signal sensitivity and intervention strategies.
Takashi D Y Kozai, Andrea S Jaquins-Gerstl, Alberto L Vazquez, Adrian C Michael, X Tracy Cui. ACS Chem Neurosci 2015
240
23

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.
Rio J Vetter, Justin C Williams, Jamille F Hetke, Elizabeth A Nunamaker, Daryl R Kipke. IEEE Trans Biomed Eng 2004
276
22

Relationship between intracortical electrode design and chronic recording function.
Lohitash Karumbaiah, Tarun Saxena, David Carlson, Ketki Patil, Radhika Patkar, Eric A Gaupp, Martha Betancur, Garrett B Stanley, Lawrence Carin, Ravi V Bellamkonda. Biomaterials 2013
135
22

Progress towards biocompatible intracortical microelectrodes for neural interfacing applications.
Mehdi Jorfi, John L Skousen, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2015
169
22

Cerebral astrocyte response to micromachined silicon implants.
J N Turner, W Shain, D H Szarowski, M Andersen, S Martins, M Isaacson, H Craighead. Exp Neurol 1999
352
20

Biomechanical analysis of silicon microelectrode-induced strain in the brain.
Hyunjung Lee, Ravi V Bellamkonda, Wei Sun, Marc E Levenston. J Neural Eng 2005
125
20

Implant size and fixation mode strongly influence tissue reactions in the CNS.
Jonas Thelin, Henrik Jörntell, Elia Psouni, Martin Garwicz, Jens Schouenborg, Nils Danielsen, Cecilia Eriksson Linsmeier. PLoS One 2011
104
20


Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.
T D Y Kozai, T C Marzullo, F Hooi, N B Langhals, A K Majewska, E B Brown, D R Kipke. J Neural Eng 2010
108
20

Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes.
Takashi D Y Kozai, Zhannetta Gugel, Xia Li, Peter J Gilgunn, Rakesh Khilwani, O Burak Ozdoganlar, Gary K Fedder, Douglas J Weber, X Tracy Cui. Biomaterials 2014
107
20

Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays.
John L Skousen, Sr Mary Elizabeth Merriam, Onnap Srivannavit, Gaytri Perlin, Kensall D Wise, Patrick A Tresco. Prog Brain Res 2011
72
23


Brain micromotion around implants in the rodent somatosensory cortex.
Aaron Gilletti, Jit Muthuswamy. J Neural Eng 2006
144
18

In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes.
Takashi D Yoshida Kozai, Alberto L Vazquez, Cassandra L Weaver, Seong-Gi Kim, X Tracy Cui. J Neural Eng 2012
117
18

Cortical neural prosthetics.
Andrew B Schwartz. Annu Rev Neurosci 2004
292
17


3D Parylene sheath neural probe for chronic recordings.
B J Kim, J T W Kuo, S A Hara, C D Lee, L Yu, C A Gutierrez, T Q Hoang, V Pikov, E Meng. J Neural Eng 2013
81
19

Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording.
Takashi D Y Kozai, Kasey Catt, Xia Li, Zhannetta V Gugel, Valur T Olafsson, Alberto L Vazquez, X Tracy Cui. Biomaterials 2015
114
17


Large-scale recording of neuronal ensembles.
György Buzsáki. Nat Neurosci 2004
916
16

Parylene flexible neural probes integrated with microfluidic channels.
Shoji Takeuchi, D Ziegler, Y Yoshida, K Mabuchi, T Suzuki. Lab Chip 2005
152
16


Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants.
Justin C Williams, Joseph A Hippensteel, John Dilgen, William Shain, Daryl R Kipke. J Neural Eng 2007
227
16

The upregulation of specific interleukin (IL) receptor antagonists and paradoxical enhancement of neuronal apoptosis due to electrode induced strain and brain micromotion.
Lohitash Karumbaiah, Sharon E Norman, Nithish B Rajan, Sanjay Anand, Tarun Saxena, Martha Betancur, Radhika Patkar, Ravi V Bellamkonda. Biomaterials 2012
63
23

The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes.
Kelsey A Potter, Amy C Buck, Wade K Self, Megan E Callanan, Smrithi Sunil, Jeffrey R Capadona. Biomaterials 2013
83
18

Curcumin-releasing mechanically adaptive intracortical implants improve the proximal neuronal density and blood-brain barrier stability.
Kelsey A Potter, Mehdi Jorfi, Kyle T Householder, E Johan Foster, Christoph Weder, Jeffrey R Capadona. Acta Biomater 2014
67
22

Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex.
D J Edell, V V Toi, V M McNeil, L D Clark. IEEE Trans Biomed Eng 1992
266
16


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.