A citation-based method for searching scientific literature

D B McCreery, W F Agnew, T G Yuen, L Bullara. IEEE Trans Biomed Eng 1990
Times Cited: 425







List of co-cited articles
889 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


Electrical stimulation of excitable tissue: design of efficacious and safe protocols.
Daniel R Merrill, Marom Bikson, John G R Jefferys. J Neurosci Methods 2005
911
39

A model of safe levels for electrical stimulation.
R V Shannon. IEEE Trans Biomed Eng 1992
260
36

Tissue damage thresholds during therapeutic electrical stimulation.
Stuart F Cogan, Kip A Ludwig, Cristin G Welle, Pavel Takmakov. J Neural Eng 2016
128
32

Neural stimulation and recording electrodes.
Stuart F Cogan. Annu Rev Biomed Eng 2008
881
26


Selection of stimulus parameters for deep brain stimulation.
Alexis M Kuncel, Warren M Grill. Clin Neurophysiol 2004
239
14







Histopathologic evaluation of prolonged intracortical electrical stimulation.
W F Agnew, T G Yuen, D B McCreery, L A Bullara. Exp Neurol 1986
102
9



A neural interface provides long-term stable natural touch perception.
Daniel W Tan, Matthew A Schiefer, Michael W Keith, James Robert Anderson, Joyce Tyler, Dustin J Tyler. Sci Transl Med 2014
357
8


Tissue damage by pulsed electrical stimulation.
A Butterwick, A Vankov, P Huie, Y Freyvert, D Palanker. IEEE Trans Biomed Eng 2007
65
12

Intracortical microstimulation of human somatosensory cortex.
Sharlene N Flesher, Jennifer L Collinger, Stephen T Foldes, Jeffrey M Weiss, John E Downey, Elizabeth C Tyler-Kabara, Sliman J Bensmaia, Andrew B Schwartz, Michael L Boninger, Robert A Gaunt. Sci Transl Med 2016
278
8


Parameters for direct cortical electrical stimulation in the human: histopathologic confirmation.
B Gordon, R P Lesser, N E Rance, J Hart, R Webber, S Uematsu, R S Fisher. Electroencephalogr Clin Neurophysiol 1990
155
7


Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes.
Stuart F Cogan, Philip R Troyk, Julia Ehrlich, Timothy D Plante, David E Detlefsen. IEEE Trans Biomed Eng 2006
78
8

Restoring natural sensory feedback in real-time bidirectional hand prostheses.
Stanisa Raspopovic, Marco Capogrosso, Francesco Maria Petrini, Marco Bonizzato, Jacopo Rigosa, Giovanni Di Pino, Jacopo Carpaneto, Marco Controzzi, Tim Boretius, Eduardo Fernandez,[...]. Sci Transl Med 2014
432
7


A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems.
Xavier Navarro, Thilo B Krueger, Natalia Lago, Silvestro Micera, Thomas Stieglitz, Paolo Dario. J Peripher Nerv Syst 2005
406
7

Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves.
T S Davis, H A C Wark, D T Hutchinson, D J Warren, K O'Neill, T Scheinblum, G A Clark, R A Normann, B Greger. J Neural Eng 2016
153
7

In vivo impedance spectroscopy of deep brain stimulation electrodes.
Scott F Lempka, Svjetlana Miocinovic, Matthew D Johnson, Jerrold L Vitek, Cameron C McIntyre. J Neural Eng 2009
120
7

Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.
James C Barrese, Naveen Rao, Kaivon Paroo, Corey Triebwasser, Carlos Vargas-Irwin, Lachlan Franquemont, John P Donoghue. J Neural Eng 2013
283
7

Damage in peripheral nerve from continuous electrical stimulation: comparison of two stimulus waveforms.
D B McCreery, W F Agnew, T G Yuen, L A Bullara. Med Biol Eng Comput 1992
65
9

Brief, noninjurious electric waveform for stimulation of the brain.
J C LILLY, J R HUGHES, E C ALVORD, T W GALKIN. Science 1955
174
6

Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus.
A L Benabid, P Pollak, C Gervason, D Hoffmann, D M Gao, M Hommel, J E Perret, J de Rougemont. Lancet 1991
6

Non-clinical and Pre-clinical Testing to Demonstrate Safety of the Barostim Neo Electrode for Activation of Carotid Baroreceptors in Chronic Human Implants.
Seth J Wilks, Seth A Hara, Erika K Ross, Evan N Nicolai, Paul A Pignato, Adam W Cates, Kip A Ludwig. Front Neurosci 2017
14
42

A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve.
Tim Boretius, Jordi Badia, Aran Pascual-Font, Martin Schuettler, Xavier Navarro, Ken Yoshida, Thomas Stieglitz. Biosens Bioelectron 2010
206
6


Direct neural sensory feedback and control of a prosthetic arm.
Gurpreet Singh Dhillon, Kenneth W Horch. IEEE Trans Neural Syst Rehabil Eng 2005
292
6

Flexible, foldable, actively multiplexed, high-density electrode array for mapping brain activity in vivo.
Jonathan Viventi, Dae-Hyeong Kim, Leif Vigeland, Eric S Frechette, Justin A Blanco, Yun-Soung Kim, Andrew E Avrin, Vineet R Tiruvadi, Suk-Won Hwang, Ann C Vanleer,[...]. Nat Neurosci 2011
456
6


Sputtered iridium oxide films for neural stimulation electrodes.
Stuart F Cogan, Julia Ehrlich, Timothy D Plante, Anton Smirnov, Douglas B Shire, Marcus Gingerich, Joseph F Rizzo. J Biomed Mater Res B Appl Biomater 2009
84
7

Response of brain tissue to chronically implanted neural electrodes.
Vadim S Polikov, Patrick A Tresco, William M Reichert. J Neurosci Methods 2005
926
6

Evaluation of poly(3,4-ethylenedioxythiophene)/carbon nanotube neural electrode coatings for stimulation in the dorsal root ganglion.
Christi L Kolarcik, Kasey Catt, Erika Rost, Ingrid N Albrecht, Dennis Bourbeau, Zhanhong Du, Takashi D Y Kozai, Xiliang Luo, Douglas J Weber, X Tracy Cui. J Neural Eng 2015
60
10

Rapid evaluation of the durability of cortical neural implants using accelerated aging with reactive oxygen species.
Pavel Takmakov, Kiersten Ruda, K Scott Phillips, Irada S Isayeva, Victor Krauthamer, Cristin G Welle. J Neural Eng 2015
79
7

Behavioral assessment of sensitivity to intracortical microstimulation of primate somatosensory cortex.
Sungshin Kim, Thierri Callier, Gregg A Tabot, Robert A Gaunt, Francesco V Tenore, Sliman J Bensmaia. Proc Natl Acad Sci U S A 2015
69
8

A Materials Roadmap to Functional Neural Interface Design.
Steven M Wellman, James R Eles, Kip A Ludwig, John P Seymour, Nicholas J Michelson, William E McFadden, Alberto L Vazquez, Takashi D Y Kozai. Adv Funct Mater 2018
123
6

Platinum for neural stimulation: voltammetry considerations.
E M Hudak, J T Mortimer, H B Martin. J Neural Eng 2010
33
18

Biomaterials. Electronic dura mater for long-term multimodal neural interfaces.
Ivan R Minev, Pavel Musienko, Arthur Hirsch, Quentin Barraud, Nikolaus Wenger, Eduardo Martin Moraud, Jérôme Gandar, Marco Capogrosso, Tomislav Milekovic, Léonie Asboth,[...]. Science 2015
415
6

Impedance characterization and modeling of electrodes for biomedical applications.
Wendy Franks, Iwan Schenker, Patrik Schmutz, Andreas Hierlemann. IEEE Trans Biomed Eng 2005
251
6

Deep brain stimulation: current challenges and future directions.
Andres M Lozano, Nir Lipsman, Hagai Bergman, Peter Brown, Stephan Chabardes, Jin Woo Chang, Keith Matthews, Cameron C McIntyre, Thomas E Schlaepfer, Michael Schulder,[...]. Nat Rev Neurol 2019
273
6

Selective microstimulation of central nervous system neurons.
C C McIntyre, W M Grill. Ann Biomed Eng 2000
145
5

Cellular effects of deep brain stimulation: model-based analysis of activation and inhibition.
Cameron C McIntyre, Warren M Grill, David L Sherman, Nitish V Thakor. J Neurophysiol 2004
494
5


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.