A citation-based method for searching scientific literature

Pavel Takmakov, Kiersten Ruda, K Scott Phillips, Irada S Isayeva, Victor Krauthamer, Cristin G Welle. J Neural Eng 2015
Times Cited: 66







List of co-cited articles
744 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


Response of brain tissue to chronically implanted neural electrodes.
Vadim S Polikov, Patrick A Tresco, William M Reichert. J Neurosci Methods 2005
844
54

Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.
James C Barrese, Naveen Rao, Kaivon Paroo, Corey Triebwasser, Carlos Vargas-Irwin, Lachlan Franquemont, John P Donoghue. J Neural Eng 2013
245
45


Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants.
Abhishek Prasad, Qing-Shan Xue, Viswanath Sankar, Toshikazu Nishida, Gerry Shaw, Wolfgang J Streit, Justin C Sanchez. J Neural Eng 2012
159
34

Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants.
Abhishek Prasad, Qing-Shan Xue, Robert Dieme, Viswanath Sankar, Roxanne C Mayrand, Toshikazu Nishida, Wolfgang J Streit, Justin C Sanchez. Front Neuroeng 2014
96
33

Progress towards biocompatible intracortical microelectrodes for neural interfacing applications.
Mehdi Jorfi, John L Skousen, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2015
144
33

Brain tissue responses to neural implants impact signal sensitivity and intervention strategies.
Takashi D Y Kozai, Andrea S Jaquins-Gerstl, Alberto L Vazquez, Adrian C Michael, X Tracy Cui. ACS Chem Neurosci 2015
202
31

Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces.
Takashi D Yoshida Kozai, Nicholas B Langhals, Paras R Patel, Xiaopei Deng, Huanan Zhang, Karen L Smith, Joerg Lahann, Nicholas A Kotov, Daryl R Kipke. Nat Mater 2012
298
27

Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording.
Takashi D Y Kozai, Kasey Catt, Xia Li, Zhannetta V Gugel, Valur T Olafsson, Alberto L Vazquez, X Tracy Cui. Biomaterials 2015
97
25

Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration.
George C McConnell, Howard D Rees, Allan I Levey, Claire-Anne Gutekunst, Robert E Gross, Ravi V Bellamkonda. J Neural Eng 2009
244
25

BBB leakage, astrogliosis, and tissue loss correlate with silicon microelectrode array recording performance.
Nicholas F Nolta, Michael B Christensen, Paul D Crane, John L Skousen, Patrick A Tresco. Biomaterials 2015
85
24

Brain responses to micro-machined silicon devices.
D H Szarowski, M D Andersen, S Retterer, A J Spence, M Isaacson, H G Craighead, J N Turner, W Shain. Brain Res 2003
441
22

Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants.
Justin C Williams, Joseph A Hippensteel, John Dilgen, William Shain, Daryl R Kipke. J Neural Eng 2007
210
22


Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes.
Takashi D Y Kozai, Zhannetta Gugel, Xia Li, Peter J Gilgunn, Rakesh Khilwani, O Burak Ozdoganlar, Gary K Fedder, Douglas J Weber, X Tracy Cui. Biomaterials 2014
96
22

The impact of chronic blood-brain barrier breach on intracortical electrode function.
Tarun Saxena, Lohitash Karumbaiah, Eric A Gaupp, Radhika Patkar, Ketki Patil, Martha Betancur, Garrett B Stanley, Ravi V Bellamkonda. Biomaterials 2013
147
22

Neural stimulation and recording electrodes.
Stuart F Cogan. Annu Rev Biomed Eng 2008
749
22



A Materials Roadmap to Functional Neural Interface Design.
Steven M Wellman, James R Eles, Kip A Ludwig, John P Seymour, Nicholas J Michelson, William E McFadden, Alberto L Vazquez, Takashi D Y Kozai. Adv Funct Mater 2018
92
21

In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes.
Takashi D Yoshida Kozai, Alberto L Vazquez, Cassandra L Weaver, Seong-Gi Kim, X Tracy Cui. J Neural Eng 2012
102
19

Cerebral astrocyte response to micromachined silicon implants.
J N Turner, W Shain, D H Szarowski, M Andersen, S Martins, M Isaacson, H Craighead. Exp Neurol 1999
337
19

Accelerated aging for testing polymeric biomaterials and medical devices.
D W L Hukins, A Mahomed, S N Kukureka. Med Eng Phys 2008
60
21

Mechanically-compliant intracortical implants reduce the neuroinflammatory response.
Jessica K Nguyen, Daniel J Park, John L Skousen, Allison E Hess-Dunning, Dustin J Tyler, Stuart J Rowan, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2014
110
19

Reach and grasp by people with tetraplegia using a neurally controlled robotic arm.
Leigh R Hochberg, Daniel Bacher, Beata Jarosiewicz, Nicolas Y Masse, John D Simeral, Joern Vogel, Sami Haddadin, Jie Liu, Sydney S Cash, Patrick van der Smagt,[...]. Nature 2012
937
18

High-performance neuroprosthetic control by an individual with tetraplegia.
Jennifer L Collinger, Brian Wodlinger, John E Downey, Wei Wang, Elizabeth C Tyler-Kabara, Douglas J Weber, Angus J C McMorland, Meel Velliste, Michael L Boninger, Andrew B Schwartz. Lancet 2013
682
18

Neural probe design for reduced tissue encapsulation in CNS.
John P Seymour, Daryl R Kipke. Biomaterials 2007
227
18

The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes.
Kelsey A Potter, Amy C Buck, Wade K Self, Megan E Callanan, Smrithi Sunil, Jeffrey R Capadona. Biomaterials 2013
75
18

Corrosion of tungsten microelectrodes used in neural recording applications.
Erin Patrick, Mark E Orazem, Justin C Sanchez, Toshikazu Nishida. J Neurosci Methods 2011
55
21

Neuronal ensemble control of prosthetic devices by a human with tetraplegia.
Leigh R Hochberg, Mijail D Serruya, Gerhard M Friehs, Jon A Mukand, Maryam Saleh, Abraham H Caplan, Almut Branner, David Chen, Richard D Penn, John P Donoghue. Nature 2006
16



A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex.
Jeyakumar Subbaroyan, David C Martin, Daryl R Kipke. J Neural Eng 2005
164
16

Relationship between intracortical electrode design and chronic recording function.
Lohitash Karumbaiah, Tarun Saxena, David Carlson, Ketki Patil, Radhika Patkar, Eric A Gaupp, Martha Betancur, Garrett B Stanley, Lawrence Carin, Ravi V Bellamkonda. Biomaterials 2013
123
16

Tissue damage thresholds during therapeutic electrical stimulation.
Stuart F Cogan, Kip A Ludwig, Cristin G Welle, Pavel Takmakov. J Neural Eng 2016
104
16

Chronic in vivo stability assessment of carbon fiber microelectrode arrays.
Paras R Patel, Huanan Zhang, Matthew T Robbins, Justin B Nofar, Shaun P Marshall, Michael J Kobylarek, Takashi D Y Kozai, Nicholas A Kotov, Cynthia A Chestek. J Neural Eng 2016
69
16

Effects of caspase-1 knockout on chronic neural recording quality and longevity: insight into cellular and molecular mechanisms of the reactive tissue response.
Takashi D Y Kozai, Xia Li, Lance M Bodily, Ellen M Caparosa, Georgios A Zenonos, Diane L Carlisle, Robert M Friedlander, X Tracy Cui. Biomaterials 2014
76
16

Glial responses to implanted electrodes in the brain.
Joseph W Salatino, Kip A Ludwig, Takashi D Y Kozai, Erin K Purcell. Nat Biomed Eng 2017
115
16

Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex.
D J Edell, V V Toi, V M McNeil, L D Clark. IEEE Trans Biomed Eng 1992
257
15

Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex.
Cynthia A Chestek, Vikash Gilja, Paul Nuyujukian, Justin D Foster, Joline M Fan, Matthew T Kaufman, Mark M Churchland, Zuley Rivera-Alvidrez, John P Cunningham, Stephen I Ryu,[...]. J Neural Eng 2011
172
15

Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion.
C S Bjornsson, S J Oh, Y A Al-Kofahi, Y J Lim, K L Smith, J N Turner, S De, B Roysam, W Shain, S J Kim. J Neural Eng 2006
174
15

Brain-controlled interfaces: movement restoration with neural prosthetics.
Andrew B Schwartz, X Tracy Cui, Douglas J Weber, Daniel W Moran. Neuron 2006
347
15

Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.
Paras R Patel, Kyounghwan Na, Huanan Zhang, Takashi D Y Kozai, Nicholas A Kotov, Euisik Yoon, Cynthia A Chestek. J Neural Eng 2015
67
15


Implantation of Neural Probes in the Brain Elicits Oxidative Stress.
Evon S Ereifej, Griffin M Rial, John K Hermann, Cara S Smith, Seth M Meade, Jacob M Rayyan, Keying Chen, He Feng, Jeffrey R Capadona. Front Bioeng Biotechnol 2018
26
38

Multi-scale, multi-modal analysis uncovers complex relationship at the brain tissue-implant neural interface: new emphasis on the biological interface.
Nicholas J Michelson, Alberto L Vazquez, James R Eles, Joseph W Salatino, Erin K Purcell, Jordan J Williams, X Tracy Cui, Takashi D Y Kozai. J Neural Eng 2018
41
24

Lifetime assessment of atomic-layer-deposited Al2O3-Parylene C bilayer coating for neural interfaces using accelerated age testing and electrochemical characterization.
Saugandhika Minnikanti, Guoqing Diao, Joseph J Pancrazio, Xianzong Xie, Loren Rieth, Florian Solzbacher, Nathalia Peixoto. Acta Biomater 2014
30
30

A comparison of the tissue response to chronically implanted Parylene-C-coated and uncoated planar silicon microelectrode arrays in rat cortex.
Brent D Winslow, Michael B Christensen, Wen-Kuo Yang, Florian Solzbacher, Patrick A Tresco. Biomaterials 2010
96
13

Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves.
T S Davis, H A C Wark, D T Hutchinson, D J Warren, K O'Neill, T Scheinblum, G A Clark, R A Normann, B Greger. J Neural Eng 2016
118
13

The insulation performance of reactive parylene films in implantable electronic devices.
John P Seymour, Yaseen M Elkasabi, Hsien-Yeh Chen, Joerg Lahann, Daryl R Kipke. Biomaterials 2009
48
18


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.