A citation-based method for searching scientific literature

Vivian A Fonseca, George Grunberger, Henry Anhalt, Timothy S Bailey, Thomas Blevins, Satish K Garg, Yehuda Handelsman, Irl B Hirsch, Eric A Orzeck, Victor Lawrence Roberts, William Tamborlane. Endocr Pract 2016
Times Cited: 98







List of co-cited articles
663 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections: The DIAMOND Randomized Clinical Trial.
Roy W Beck, Tonya Riddlesworth, Katrina Ruedy, Andrew Ahmann, Richard Bergenstal, Stacie Haller, Craig Kollman, Davida Kruger, Janet B McGill, William Polonsky,[...]. JAMA 2017
364
37

International Consensus on Use of Continuous Glucose Monitoring.
Thomas Danne, Revital Nimri, Tadej Battelino, Richard M Bergenstal, Kelly L Close, J Hans DeVries, Satish Garg, Lutz Heinemann, Irl Hirsch, Stephanie A Amiel,[...]. Diabetes Care 2017
536
36

Continuous glucose monitoring and intensive treatment of type 1 diabetes.
William V Tamborlane, Roy W Beck, Bruce W Bode, Bruce Buckingham, H Peter Chase, Robert Clemons, Rosanna Fiallo-Scharer, Larry A Fox, Lisa K Gilliam, Irl B Hirsch,[...]. N Engl J Med 2008
869
27

Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial.
Jan Bolinder, Ramiro Antuna, Petronella Geelhoed-Duijvestijn, Jens Kröger, Raimund Weitgasser. Lancet 2016
327
27

Diabetes Technology-Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults: An Endocrine Society Clinical Practice Guideline.
Anne L Peters, Andrew J Ahmann, Tadej Battelino, Alison Evert, Irl B Hirsch, M Hassan Murad, William E Winter, Howard Wolpert. J Clin Endocrinol Metab 2016
89
30


Recommendations for standardizing glucose reporting and analysis to optimize clinical decision making in diabetes: the Ambulatory Glucose Profile (AGP).
Richard M Bergenstal, Andrew J Ahmann, Timothy Bailey, Roy W Beck, Joan Bissen, Bruce Buckingham, Larry Deeb, Robert H Dolin, Satish K Garg, Robin Goland,[...]. Diabetes Technol Ther 2013
142
24

Continuous Glucose Monitoring vs Conventional Therapy for Glycemic Control in Adults With Type 1 Diabetes Treated With Multiple Daily Insulin Injections: The GOLD Randomized Clinical Trial.
Marcus Lind, William Polonsky, Irl B Hirsch, Tim Heise, Jan Bolinder, Sofia Dahlqvist, Erik Schwarz, Arndís Finna Ólafsdóttir, Anders Frid, Hans Wedel,[...]. JAMA 2017
240
24

REPLACE-BG: A Randomized Trial Comparing Continuous Glucose Monitoring With and Without Routine Blood Glucose Monitoring in Adults With Well-Controlled Type 1 Diabetes.
Grazia Aleppo, Katrina J Ruedy, Tonya D Riddlesworth, Davida F Kruger, Anne L Peters, Irl Hirsch, Richard M Bergenstal, Elena Toschi, Andrew J Ahmann, Viral N Shah,[...]. Diabetes Care 2017
112
20


Continuous Glucose Monitoring Versus Usual Care in Patients With Type 2 Diabetes Receiving Multiple Daily Insulin Injections: A Randomized Trial.
Roy W Beck, Tonya D Riddlesworth, Katrina Ruedy, Andrew Ahmann, Stacie Haller, Davida Kruger, Janet B McGill, William Polonsky, David Price, Stephen Aronoff,[...]. Ann Intern Med 2017
141
17

The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System.
Timothy Bailey, Bruce W Bode, Mark P Christiansen, Leslie J Klaff, Shridhara Alva. Diabetes Technol Ther 2015
282
16

Short- and long-term effects of real-time continuous glucose monitoring in patients with type 2 diabetes.
Robert A Vigersky, Stephanie J Fonda, Mary Chellappa, M Susan Walker, Nicole M Ehrhardt. Diabetes Care 2012
116
15

Threshold-based insulin-pump interruption for reduction of hypoglycemia.
Richard M Bergenstal, David C Klonoff, Satish K Garg, Bruce W Bode, Melissa Meredith, Robert H Slover, Andrew J Ahmann, John B Welsh, Scott W Lee, Francine R Kaufman. N Engl J Med 2013
355
15

Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D Exchange clinic registry.
Kellee M Miller, Nicole C Foster, Roy W Beck, Richard M Bergenstal, Stephanie N DuBose, Linda A DiMeglio, David M Maahs, William V Tamborlane. Diabetes Care 2015
719
15

Role of continuous glucose monitoring for type 2 in diabetes management and research.
Robert Vigersky, Maneesh Shrivastav. J Diabetes Complications 2017
43
34


Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes.
Richard M Bergenstal, Satish Garg, Stuart A Weinzimer, Bruce A Buckingham, Bruce W Bode, William V Tamborlane, Francine R Kaufman. JAMA 2016
269
15

Ambulatory glucose profile: representation of verified self-monitored blood glucose data.
R S Mazze, D Lucido, O Langer, K Hartmann, D Rodbard. Diabetes Care 1987
68
22

Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial.
Cornelis A J van Beers, J Hans DeVries, Susanne J Kleijer, Mark M Smits, Petronella H Geelhoed-Duijvestijn, Mark H H Kramer, Michaela Diamant, Frank J Snoek, Erik H Serné. Lancet Diabetes Endocrinol 2016
140
15

Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry.
Jenise C Wong, Nicole C Foster, David M Maahs, Dan Raghinaru, Richard M Bergenstal, Andrew J Ahmann, Anne L Peters, Bruce W Bode, Grazia Aleppo, Irl B Hirsch,[...]. Diabetes Care 2014
182
13

Clinical Use of Continuous Glucose Monitoring in Adults with Type 2 Diabetes.
Anders L Carlson, Deborah M Mullen, Richard M Bergenstal. Diabetes Technol Ther 2017
54
24

Characterizing glucose exposure for individuals with normal glucose tolerance using continuous glucose monitoring and ambulatory glucose profile analysis.
Roger S Mazze, Ellie Strock, David Wesley, Sarah Borgman, Blaine Morgan, Richard Bergenstal, Robert Cuddihy. Diabetes Technol Ther 2008
103
13

AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS AND AMERICAN COLLEGE OF ENDOCRINOLOGY 2016 OUTPATIENT GLUCOSE MONITORING CONSENSUS STATEMENT.
Timothy S Bailey, George Grunberger, Bruce W Bode, Yehuda Handelsman, Irl B Hirsch, Lois Jovanovič, Victor Lawrence Roberts, David Rodbard, William V Tamborlane, John Walsh. Endocr Pract 2016
68
19

Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes.
Richard M Bergenstal, William V Tamborlane, Andrew Ahmann, John B Buse, George Dailey, Stephen N Davis, Carol Joyce, Tim Peoples, Bruce A Perkins, John B Welsh,[...]. N Engl J Med 2010
482
12

Assessing sensor accuracy for non-adjunct use of continuous glucose monitoring.
Boris P Kovatchev, Stephen D Patek, Edward Andrew Ortiz, Marc D Breton. Diabetes Technol Ther 2015
100
12

The effect of continuous glucose monitoring in well-controlled type 1 diabetes.
Roy W Beck, Irl B Hirsch, Lori Laffel, William V Tamborlane, Bruce W Bode, Bruce Buckingham, Peter Chase, Robert Clemons, Rosanna Fiallo-Scharer, Larry A Fox,[...]. Diabetes Care 2009
245
12



The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial.
T Battelino, I Conget, B Olsen, I Schütz-Fuhrmann, E Hommel, R Hoogma, U Schierloh, N Sulli, J Bolinder. Diabetologia 2012
251
12



Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range.
Tadej Battelino, Thomas Danne, Richard M Bergenstal, Stephanie A Amiel, Roy Beck, Torben Biester, Emanuele Bosi, Bruce A Buckingham, William T Cefalu, Kelly L Close,[...]. Diabetes Care 2019
491
12


Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis.
Hsin-Chieh Yeh, Todd T Brown, Nisa Maruthur, Padmini Ranasinghe, Zackary Berger, Yong D Suh, Lisa M Wilson, Elisabeth B Haberl, Jessica Brick, Eric B Bass,[...]. Ann Intern Med 2012
259
11


Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes.
Satish K Garg, Stuart A Weinzimer, William V Tamborlane, Bruce A Buckingham, Bruce W Bode, Timothy S Bailey, Ronald L Brazg, Jacob Ilany, Robert H Slover, Stacey M Anderson,[...]. Diabetes Technol Ther 2017
241
11

6. Glycemic Targets.
. Diabetes Care 2017
208
11

Glucose Management Indicator (GMI): A New Term for Estimating A1C From Continuous Glucose Monitoring.
Richard M Bergenstal, Roy W Beck, Kelly L Close, George Grunberger, David B Sacks, Aaron Kowalski, Adam S Brown, Lutz Heinemann, Grazia Aleppo, Donna B Ryan,[...]. Diabetes Care 2018
121
11

Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes.
Tadej Battelino, Moshe Phillip, Natasa Bratina, Revital Nimri, Per Oskarsson, Jan Bolinder. Diabetes Care 2011
250
10

Translating the A1C assay into estimated average glucose values.
David M Nathan, Judith Kuenen, Rikke Borg, Hui Zheng, David Schoenfeld, Robert J Heine. Diabetes Care 2008
801
10

Rate of hypoglycemia in insulin-treated patients with type 2 diabetes can be predicted from glycemic variability data.
Yongming Qu, Scott J Jacober, Qianyi Zhang, Linda L Wolka, J Hans DeVries. Diabetes Technol Ther 2012
79
12



Optimal Sampling Duration for Continuous Glucose Monitoring to Determine Long-Term Glycemic Control.
Tonya D Riddlesworth, Roy W Beck, Robin L Gal, Crystal G Connor, Richard M Bergenstal, Sooji Lee, Steven M Willi. Diabetes Technol Ther 2018
67
14

A Practical Approach to Using Trend Arrows on the Dexcom G5 CGM System for the Management of Adults With Diabetes.
Grazia Aleppo, Lori M Laffel, Andrew J Ahmann, Irl B Hirsch, Davida F Kruger, Anne Peters, Ruth S Weinstock, Dennis R Harris. J Endocr Soc 2017
41
24

Activation of oxidative stress by acute glucose fluctuations compared with sustained chronic hyperglycemia in patients with type 2 diabetes.
Louis Monnier, Emilie Mas, Christine Ginet, Françoise Michel, Laetitia Villon, Jean-Paul Cristol, Claude Colette. JAMA 2006
9

Evidence of a strong association between frequency of self-monitoring of blood glucose and hemoglobin A1c levels in T1D exchange clinic registry participants.
Kellee M Miller, Roy W Beck, Richard M Bergenstal, Robin S Goland, Michael J Haller, Janet B McGill, Henry Rodriguez, Jill H Simmons, Irl B Hirsch. Diabetes Care 2013
245
9

Head-to-head comparison between flash and continuous glucose monitoring systems in outpatients with type 1 diabetes.
B Bonora, A Maran, S Ciciliot, A Avogaro, G P Fadini. J Endocrinol Invest 2016
55
16

Optimal sampling intervals to assess long-term glycemic control using continuous glucose monitoring.
Dongyuan Xing, Craig Kollman, Roy W Beck, William V Tamborlane, Lori Laffel, Bruce A Buckingham, Darrell M Wilson, Stuart Weinzimer, Rosanna Fiallo-Scharer, Katrina J Ruedy. Diabetes Technol Ther 2011
46
19


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.