A citation-based method for searching scientific literature

Zhanhong Jeff Du, Christi L Kolarcik, Takashi D Y Kozai, Silvia D Luebben, Shawn A Sapp, Xin Sally Zheng, James A Nabity, X Tracy Cui. Acta Biomater 2017
Times Cited: 74







List of co-cited articles
992 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


Brain tissue responses to neural implants impact signal sensitivity and intervention strategies.
Takashi D Y Kozai, Andrea S Jaquins-Gerstl, Alberto L Vazquez, Adrian C Michael, X Tracy Cui. ACS Chem Neurosci 2015
229
50

Response of brain tissue to chronically implanted neural electrodes.
Vadim S Polikov, Patrick A Tresco, William M Reichert. J Neurosci Methods 2005
896
44


Ultraflexible nanoelectronic probes form reliable, glial scar-free neural integration.
Lan Luan, Xiaoling Wei, Zhengtuo Zhao, Jennifer J Siegel, Ojas Potnis, Catherine A Tuppen, Shengqing Lin, Shams Kazmi, Robert A Fowler, Stewart Holloway,[...]. Sci Adv 2017
187
40

Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces.
Takashi D Yoshida Kozai, Nicholas B Langhals, Paras R Patel, Xiaopei Deng, Huanan Zhang, Karen L Smith, Joerg Lahann, Nicholas A Kotov, Daryl R Kipke. Nat Mater 2012
329
37

Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.
James C Barrese, Naveen Rao, Kaivon Paroo, Corey Triebwasser, Carlos Vargas-Irwin, Lachlan Franquemont, John P Donoghue. J Neural Eng 2013
269
32

Chronic tissue response to carboxymethyl cellulose based dissolvable insertion needle for ultra-small neural probes.
Takashi D Y Kozai, Zhannetta Gugel, Xia Li, Peter J Gilgunn, Rakesh Khilwani, O Burak Ozdoganlar, Gary K Fedder, Douglas J Weber, X Tracy Cui. Biomaterials 2014
104
32

Mechanically-compliant intracortical implants reduce the neuroinflammatory response.
Jessica K Nguyen, Daniel J Park, John L Skousen, Allison E Hess-Dunning, Dustin J Tyler, Stuart J Rowan, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2014
118
31

Glial responses to implanted electrodes in the brain.
Joseph W Salatino, Kip A Ludwig, Takashi D Y Kozai, Erin K Purcell. Nat Biomed Eng 2017
167
29

Neural stimulation and recording electrodes.
Stuart F Cogan. Annu Rev Biomed Eng 2008
835
28

Effects of caspase-1 knockout on chronic neural recording quality and longevity: insight into cellular and molecular mechanisms of the reactive tissue response.
Takashi D Y Kozai, Xia Li, Lance M Bodily, Ellen M Caparosa, Georgios A Zenonos, Diane L Carlisle, Robert M Friedlander, X Tracy Cui. Biomaterials 2014
84
28

Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants.
Abhishek Prasad, Qing-Shan Xue, Viswanath Sankar, Toshikazu Nishida, Gerry Shaw, Wolfgang J Streit, Justin C Sanchez. J Neural Eng 2012
167
28

Neural probe design for reduced tissue encapsulation in CNS.
John P Seymour, Daryl R Kipke. Biomaterials 2007
241
28

Brain responses to micro-machined silicon devices.
D H Szarowski, M D Andersen, S Retterer, A J Spence, M Isaacson, H G Craighead, J N Turner, W Shain. Brain Res 2003
464
28

Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording.
Takashi D Y Kozai, Kasey Catt, Xia Li, Zhannetta V Gugel, Valur T Olafsson, Alberto L Vazquez, X Tracy Cui. Biomaterials 2015
111
27

A Materials Roadmap to Functional Neural Interface Design.
Steven M Wellman, James R Eles, Kip A Ludwig, John P Seymour, Nicholas J Michelson, William E McFadden, Alberto L Vazquez, Takashi D Y Kozai. Adv Funct Mater 2018
119
27

Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants.
Abhishek Prasad, Qing-Shan Xue, Robert Dieme, Viswanath Sankar, Roxanne C Mayrand, Toshikazu Nishida, Wolfgang J Streit, Justin C Sanchez. Front Neuroeng 2014
108
25

The impact of chronic blood-brain barrier breach on intracortical electrode function.
Tarun Saxena, Lohitash Karumbaiah, Eric A Gaupp, Radhika Patkar, Ketki Patil, Martha Betancur, Garrett B Stanley, Ravi V Bellamkonda. Biomaterials 2013
157
25

Fully integrated silicon probes for high-density recording of neural activity.
James J Jun, Nicholas A Steinmetz, Joshua H Siegle, Daniel J Denman, Marius Bauza, Brian Barbarits, Albert K Lee, Costas A Anastassiou, Alexandru Andrei, Çağatay Aydın,[...]. Nature 2017
586
25

In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes.
Takashi D Yoshida Kozai, Alberto L Vazquez, Cassandra L Weaver, Seong-Gi Kim, X Tracy Cui. J Neural Eng 2012
111
22

Biomaterials. Electronic dura mater for long-term multimodal neural interfaces.
Ivan R Minev, Pavel Musienko, Arthur Hirsch, Quentin Barraud, Nikolaus Wenger, Eduardo Martin Moraud, Jérôme Gandar, Marco Capogrosso, Tomislav Milekovic, Léonie Asboth,[...]. Science 2015
401
22

Progress towards biocompatible intracortical microelectrodes for neural interfacing applications.
Mehdi Jorfi, John L Skousen, Christoph Weder, Jeffrey R Capadona. J Neural Eng 2015
164
22


Multi-scale, multi-modal analysis uncovers complex relationship at the brain tissue-implant neural interface: new emphasis on the biological interface.
Nicholas J Michelson, Alberto L Vazquez, James R Eles, Joseph W Salatino, Erin K Purcell, Jordan J Williams, X Tracy Cui, Takashi D Y Kozai. J Neural Eng 2018
55
30

Brain micromotion around implants in the rodent somatosensory cortex.
Aaron Gilletti, Jit Muthuswamy. J Neural Eng 2006
143
22

Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.
Paras R Patel, Kyounghwan Na, Huanan Zhang, Takashi D Y Kozai, Nicholas A Kotov, Euisik Yoon, Cynthia A Chestek. J Neural Eng 2015
75
21

Syringe-injectable electronics.
Jia Liu, Tian-Ming Fu, Zengguang Cheng, Guosong Hong, Tao Zhou, Lihua Jin, Madhavi Duvvuri, Zhe Jiang, Peter Kruskal, Chong Xie,[...]. Nat Nanotechnol 2015
271
21

Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration.
George C McConnell, Howard D Rees, Allan I Levey, Claire-Anne Gutekunst, Robert E Gross, Ravi V Bellamkonda. J Neural Eng 2009
257
21

Neuroadhesive L1 coating attenuates acute microglial attachment to neural electrodes as revealed by live two-photon microscopy.
James R Eles, Alberto L Vazquez, Noah R Snyder, Carl Lagenaur, Matthew C Murphy, Takashi D Y Kozai, X Tracy Cui. Biomaterials 2017
49
32

Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants.
Justin C Williams, Joseph A Hippensteel, John Dilgen, William Shain, Daryl R Kipke. J Neural Eng 2007
220
21


Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion.
C S Bjornsson, S J Oh, Y A Al-Kofahi, Y J Lim, K L Smith, J N Turner, S De, B Roysam, W Shain, S J Kim. J Neural Eng 2006
184
21

A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex.
Jeyakumar Subbaroyan, David C Martin, Daryl R Kipke. J Neural Eng 2005
177
21

Histological evaluation of flexible neural implants; flexibility limit for reducing the tissue response?
Heui Chang Lee, Fredrik Ejserholm, Janak Gaire, Seth Currlin, Jens Schouenborg, Lars Wallman, Martin Bengtsson, Kinam Park, Kevin J Otto. J Neural Eng 2017
45
33

Chronic in vivo stability assessment of carbon fiber microelectrode arrays.
Paras R Patel, Huanan Zhang, Matthew T Robbins, Justin B Nofar, Shaun P Marshall, Michael J Kobylarek, Takashi D Y Kozai, Nicholas A Kotov, Cynthia A Chestek. J Neural Eng 2016
87
20

Chronic In Vivo Evaluation of PEDOT/CNT for Stable Neural Recordings.
Takashi D Y Kozai, Kasey Catt, Zhanhong Du, Kyounghwan Na, Onnop Srivannavit, Razi-Ul M Haque, John Seymour, Kensall D Wise, Euisik Yoon, Xinyan Tracy Cui. IEEE Trans Biomed Eng 2016
74
20

Relationship between intracortical electrode design and chronic recording function.
Lohitash Karumbaiah, Tarun Saxena, David Carlson, Ketki Patil, Radhika Patkar, Eric A Gaupp, Martha Betancur, Garrett B Stanley, Lawrence Carin, Ravi V Bellamkonda. Biomaterials 2013
130
20

Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex.
J C Williams, R L Rennaker, D R Kipke. Brain Res Brain Res Protoc 1999
227
18

Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.
T D Y Kozai, T C Marzullo, F Hooi, N B Langhals, A K Majewska, E B Brown, D R Kipke. J Neural Eng 2010
105
18

Syringe-injectable mesh electronics integrate seamlessly with minimal chronic immune response in the brain.
Tao Zhou, Guosong Hong, Tian-Ming Fu, Xiao Yang, Thomas G Schuhmann, Robert D Viveros, Charles M Lieber. Proc Natl Acad Sci U S A 2017
83
18


Nanofabricated Ultraflexible Electrode Arrays for High-Density Intracortical Recording.
Xiaoling Wei, Lan Luan, Zhengtuo Zhao, Xue Li, Hanlin Zhu, Ojas Potnis, Chong Xie. Adv Sci (Weinh) 2018
46
30

In vivo imaging of neuronal calcium during electrode implantation: Spatial and temporal mapping of damage and recovery.
James R Eles, Alberto L Vazquez, Takashi D Y Kozai, X Tracy Cui. Biomaterials 2018
41
34

Characterization of Mechanically Matched Hydrogel Coatings to Improve the Biocompatibility of Neural Implants.
Kevin C Spencer, Jay C Sy, Khalil B Ramadi, Ann M Graybiel, Robert Langer, Michael J Cima. Sci Rep 2017
67
19

Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes.
Chong Xie, Jia Liu, Tian-Ming Fu, Xiaochuan Dai, Wei Zhou, Charles M Lieber. Nat Mater 2015
168
17

Electrical stimulation of excitable tissue: design of efficacious and safe protocols.
Daniel R Merrill, Marom Bikson, John G R Jefferys. J Neurosci Methods 2005
849
17

NeuroGrid: recording action potentials from the surface of the brain.
Dion Khodagholy, Jennifer N Gelinas, Thomas Thesen, Werner Doyle, Orrin Devinsky, George G Malliaras, György Buzsáki. Nat Neurosci 2015
325
17

Reach and grasp by people with tetraplegia using a neurally controlled robotic arm.
Leigh R Hochberg, Daniel Bacher, Beata Jarosiewicz, Nicolas Y Masse, John D Simeral, Joern Vogel, Sami Haddadin, Jie Liu, Sydney S Cash, Patrick van der Smagt,[...]. Nature 2012
17

Neural Recording and Modulation Technologies.
Ritchie Chen, Andres Canales, Polina Anikeeva. Nat Rev Mater 2017
168
16

Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.
J P Harris, J R Capadona, R H Miller, B C Healy, K Shanmuganathan, S J Rowan, C Weder, D J Tyler. J Neural Eng 2011
105
16


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.