A citation-based method for searching scientific literature

Thomas A Peyser, Andrew K Balo, Bruce A Buckingham, Irl B Hirsch, Arturo Garcia. Diabetes Technol Ther 2018
Times Cited: 26







List of co-cited articles
117 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


International Consensus on Use of Continuous Glucose Monitoring.
Thomas Danne, Revital Nimri, Tadej Battelino, Richard M Bergenstal, Kelly L Close, J Hans DeVries, Satish Garg, Lutz Heinemann, Irl Hirsch, Stephanie A Amiel,[...]. Diabetes Care 2017
536
46


Symmetrization of the blood glucose measurement scale and its applications.
B P Kovatchev, D J Cox, L A Gonder-Frederick, W Clarke. Diabetes Care 1997
145
34


Statistical tools to analyze continuous glucose monitor data.
William Clarke, Boris Kovatchev. Diabetes Technol Ther 2009
120
26

Glucose variability is associated with intensive care unit mortality.
Jeroen Hermanides, Titia M Vriesendorp, Robert J Bosman, Durk F Zandstra, Joost B Hoekstra, J Hans Devries. Crit Care Med 2010
258
26

Mean amplitude of glycemic excursions, a measure of diabetic instability.
F J Service, G D Molnar, J W Rosevear, E Ackerman, L C Gatewood, W F Taylor. Diabetes 1970
656
26


A novel approach to continuous glucose analysis utilizing glycemic variation.
C M McDonnell, S M Donath, S I Vidmar, G A Werther, F J Cameron. Diabetes Technol Ther 2005
208
26



Characterizing blood glucose variability using new metrics with continuous glucose monitoring data.
Cynthia R Marling, Jay H Shubrook, Stanley J Vernier, Matthew T Wiley, Frank L Schwartz. J Diabetes Sci Technol 2011
32
19

Toward Defining the Threshold Between Low and High Glucose Variability in Diabetes.
Louis Monnier, Claude Colette, Anne Wojtusciszyn, Sylvie Dejager, Eric Renard, Nicolas Molinari, David R Owens. Diabetes Care 2017
116
19

Normal reference range for mean tissue glucose and glycemic variability derived from continuous glucose monitoring for subjects without diabetes in different ethnic groups.
Nathan R Hill, Nick S Oliver, Pratik Choudhary, Jonathan C Levy, Peter Hindmarsh, David R Matthews. Diabetes Technol Ther 2011
161
19

Glucose variability indices in type 1 diabetes: parsimonious set of indices revealed by sparse principal component analysis.
Chiara Fabris, Andrea Facchinetti, Giovanni Sparacino, Mattia Zanon, Stefania Guerra, Alberto Maran, Claudio Cobelli. Diabetes Technol Ther 2014
29
19

A method for assessing quality of control from glucose profiles.
N R Hill, P C Hindmarsh, R J Stevens, I M Stratton, J C Levy, D R Matthews. Diabet Med 2007
77
19

Recommendations for standardizing glucose reporting and analysis to optimize clinical decision making in diabetes: the Ambulatory Glucose Profile (AGP).
Richard M Bergenstal, Andrew J Ahmann, Timothy Bailey, Roy W Beck, Joan Bissen, Bruce Buckingham, Larry Deeb, Robert H Dolin, Satish K Garg, Robin Goland,[...]. Diabetes Technol Ther 2013
142
19

Glycemic Variability: How Do We Measure It and Why Is It Important?
Sunghwan Suh, Jae Hyeon Kim. Diabetes Metab J 2015
131
19

Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range.
Tadej Battelino, Thomas Danne, Richard M Bergenstal, Stephanie A Amiel, Roy Beck, Torben Biester, Emanuele Bosi, Bruce A Buckingham, William T Cefalu, Kelly L Close,[...]. Diabetes Care 2019
491
19


Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application.
Boris P Kovatchev, William L Clarke, Marc Breton, Kenneth Brayman, Anthony McCall. Diabetes Technol Ther 2005
116
15

A Simple Composite Metric for the Assessment of Glycemic Status from Continuous Glucose Monitoring Data: Implications for Clinical Practice and the Artificial Pancreas.
Irl B Hirsch, Andrew K Balo, Kevin Sayer, Arturo Garcia, Bruce A Buckingham, Thomas A Peyser. Diabetes Technol Ther 2017
21
19

Measures of Glycemic Variability in Type 1 Diabetes and the Effect of Real-Time Continuous Glucose Monitoring.
Ahmed H El-Laboudi, Ian F Godsland, Desmond G Johnston, Nick S Oliver. Diabetes Technol Ther 2016
36
15

Improved quality of glycemic control and reduced glycemic variability with use of continuous glucose monitoring.
David Rodbard, Timothy Bailey, Lois Jovanovic, Howard Zisser, Roy Kaplan, Satish K Garg. Diabetes Technol Ther 2009
92
15

The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System.
Timothy Bailey, Bruce W Bode, Mark P Christiansen, Leslie J Klaff, Shridhara Alva. Diabetes Technol Ther 2015
282
15


Parsimonious Description of Glucose Variability in Type 2 Diabetes by Sparse Principal Component Analysis.
Chiara Fabris, Andrea Facchinetti, Giuseppe Fico, Francesco Sambo, Maria Teresa Arredondo, Claudio Cobelli. J Diabetes Sci Technol 2015
21
19

THE M-VALVE, AN INDEX OF BLOOD-SUGAR CONTROL IN DIABETICS.
J SCHLICHTKRULL, O MUNCK, M JERSILD. Acta Med Scand 1965
258
15



Evaluation of a new measure of blood glucose variability in diabetes.
Boris P Kovatchev, Erik Otto, Daniel Cox, Linda Gonder-Frederick, William Clarke. Diabetes Care 2006
206
15

Translating the A1C assay into estimated average glucose values.
David M Nathan, Judith Kuenen, Rikke Borg, Hui Zheng, David Schoenfeld, Robert J Heine. Diabetes Care 2008
801
11

A consensus perceived glycemic variability metric.
Cynthia R Marling, Nigel W Struble, Razvan C Bunescu, Jay H Shubrook, Frank L Schwartz. J Diabetes Sci Technol 2013
14
21

Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections: The DIAMOND Randomized Clinical Trial.
Roy W Beck, Tonya Riddlesworth, Katrina Ruedy, Andrew Ahmann, Richard Bergenstal, Stacie Haller, Craig Kollman, Davida Kruger, Janet B McGill, William Polonsky,[...]. JAMA 2017
364
11

Recommendations for standardizing glucose reporting and analysis to optimize clinical decision making in diabetes: the ambulatory glucose profile.
Richard M Bergenstal, Andrew J Ahmann, Timothy Bailey, Roy W Beck, Joan Bissen, Bruce Buckingham, Larry Deeb, Robert H Dolin, Satish K Garg, Robin Goland,[...]. J Diabetes Sci Technol 2013
64
11

The "glucose pentagon": assessing glycemic control of patients with diabetes mellitus by a model integrating different parameters from glucose profiles.
Andreas Thomas, Martin Schönauer, Frank Achermann, Oliver Schnell, Markolf Hanefeld, Hans-Jürgen Ziegelasch, John Mastrototaro, Lutz Heinemann. Diabetes Technol Ther 2009
26
11

Glycemic variability: it's not just about A1C anymore!
Irl B Hirsch. Diabetes Technol Ther 2005
83
11




Long-term Glycemic Variability and Risk of Adverse Outcomes: A Systematic Review and Meta-analysis.
Catherine Gorst, Chun Shing Kwok, Saadia Aslam, Iain Buchan, Evangelos Kontopantelis, Phyo K Myint, Grant Heatlie, Yoon Loke, Martin K Rutter, Mamas A Mamas. Diabetes Care 2015
203
11

Yet Another Glucose Variability Index: Time for a Paradigm Change?
Claudio Cobelli, Andrea Facchinetti. Diabetes Technol Ther 2018
6
50

The Comprehensive Glucose Pentagon: A Glucose-Centric Composite Metric for Assessing Glycemic Control in Persons With Diabetes.
Robert A Vigersky, John Shin, Boyi Jiang, Thorsten Siegmund, Chantal McMahon, Andreas Thomas. J Diabetes Sci Technol 2018
20
15

Outcome Measures for Artificial Pancreas Clinical Trials: A Consensus Report.
David M Maahs, Bruce A Buckingham, Jessica R Castle, Ali Cinar, Edward R Damiano, Eyal Dassau, J Hans DeVries, Francis J Doyle, Steven C Griffen, Ahmad Haidar,[...]. Diabetes Care 2016
95
11

Q-Score: development of a new metric for continuous glucose monitoring that enables stratification of antihyperglycaemic therapies.
Petra Augstein, Peter Heinke, Lutz Vogt, Roberto Vogt, Christine Rackow, Klaus-Dieter Kohnert, Eckhard Salzsieder. BMC Endocr Disord 2015
23
13

Associations of blood glucose dynamics with antihyperglycemic treatment and glycemic variability in type 1 and type 2 diabetes.
K-D Kohnert, P Heinke, L Vogt, P Augstein, A Thomas, E Salzsieder. J Endocrinol Invest 2017
8
37



Continuous glucose monitoring after islet transplantation in type 1 diabetes: an excellent graft function (β-score greater than 7) Is required to abrogate hyperglycemia, whereas a minimal function is necessary to suppress severe hypoglycemia (β-score greater than 3).
Marie-Christine Vantyghem, Violeta Raverdy, Anne-Sophie Balavoine, Frédérique Defrance, Robert Caiazzo, Laurent Arnalsteen, Valéry Gmyr, Marc Hazzan, Christian Noël, Julie Kerr-Conte,[...]. J Clin Endocrinol Metab 2012
61
11

Glucose variability: An emerging target for the treatment of diabetes mellitus.
Simona Frontoni, Paolo Di Bartolo, Angelo Avogaro, Emanuele Bosi, Giuseppe Paolisso, Antonio Ceriello. Diabetes Res Clin Pract 2013
82
11


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.