A citation-based method for searching scientific literature

Johannes B Erhardt, Erwin Fuhrer, Oliver G Gruschke, Jochen Leupold, Matthias C Wapler, Jürgen Hennig, Thomas Stieglitz, Jan G Korvink. J Neural Eng 2018
Times Cited: 44







List of co-cited articles
202 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: case report.
Jaimie M Henderson, Jean Tkach, Michael Phillips, Kenneth Baker, Frank G Shellock, Ali R Rezai. Neurosurgery 2005
177
22

Adverse events and discomfort during magnetic resonance imaging in cochlear implant recipients.
Bo Gyung Kim, Jin Won Kim, Jeong Jin Park, Sung Huhn Kim, Hee Nam Kim, Jae Young Choi. JAMA Otolaryngol Head Neck Surg 2015
64
15

Magnetic Resonance Imaging With Cochlear Implant Magnet in Place: Safety and Imaging Quality.
Matthew L Carlson, Brian A Neff, Michael J Link, John I Lane, Robert E Watson, Kiaran P McGee, Matt A Bernstein, Colin L W Driscoll. Otol Neurotol 2015
87
15

Neurostimulation systems for deep brain stimulation: in vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla.
Ali R Rezai, Daniel Finelli, John A Nyenhuis, Greg Hrdlicka, Jean Tkach, Ashwini Sharan, Paul Rugieri, Paul H Stypulkowski, Frank G Shellock. J Magn Reson Imaging 2002
188
15

Deep brain stimulation induces BOLD activation in motor and non-motor networks: an fMRI comparison study of STN and EN/GPi DBS in large animals.
Hoon-Ki Min, Sun-Chul Hwang, Michael P Marsh, Inyong Kim, Emily Knight, Bryan Striemer, Joel P Felmlee, Kirk M Welker, Charles D Blaha, Su-Youne Chang,[...]. Neuroimage 2012
76
13

Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of Parkinson disease. Case report.
Jörg Spiegel, Gerhard Fuss, Martin Backens, Wolfgang Reith, Tim Magnus, Georg Becker, Jean-Richard Moringlane, Ulrich Dillmann. J Neurosurg 2003
106
13

The physics of MRI safety.
Lawrence P Panych, Bruno Madore. J Magn Reson Imaging 2018
58
13

Construction and modeling of a reconfigurable MRI coil for lowering SAR in patients with deep brain stimulation implants.
Laleh Golestanirad, Maria Ida Iacono, Boris Keil, Leonardo M Angelone, Giorgio Bonmassar, Michael D Fox, Todd Herrington, Elfar Adalsteinsson, Cristen LaPierre, Azma Mareyam,[...]. Neuroimage 2017
36
13

MRI information for commonly used otologic implants: review and update.
Roya Azadarmaki, Rhonda Tubbs, Douglas A Chen, Frank G Shellock. Otolaryngol Head Neck Surg 2014
26
19

Revision surgery due to magnet dislocation in cochlear implant patients: an emerging complication.
Frederike Hassepass, Vanessa Stabenau, Wolfgang Maier, Susan Arndt, Roland Laszig, Rainer Beck, Antje Aschendorff. Otol Neurotol 2014
40
12

Functional MRI with active, fully implanted, deep brain stimulation systems: safety and experimental confounds.
David W Carmichael, Serge Pinto, Patricia Limousin-Dowsey, Stephane Thobois, Philip J Allen, Louis Lemieux, Tarek Yousry, John S Thornton. Neuroimage 2007
77
11

Clinical safety of brain magnetic resonance imaging with implanted deep brain stimulation hardware: large case series and review of the literature.
Ludvic Zrinzo, Fumiaki Yoshida, Marwan I Hariz, John Thornton, Thomas Foltynie, Tarek A Yousry, Patricia Limousin. World Neurosurg 2011
64
11


Complexity of MRI induced heating on metallic leads: experimental measurements of 374 configurations.
Eugenio Mattei, Michele Triventi, Giovanni Calcagnini, Federica Censi, Wolfgang Kainz, Gonzalo Mendoza, Howard I Bassen, Pietro Bartolini. Biomed Eng Online 2008
91
11

A novel brain stimulation technology provides compatibility with MRI.
Peter Serano, Leonardo M Angelone, Husam Katnani, Emad Eskandar, Giorgio Bonmassar. Sci Rep 2015
42
11

MRI-Related Heating of Implants and Devices: A Review.
Lukas Winter, Frank Seifert, Luca Zilberti, Manuel Murbach, Bernd Ittermann. J Magn Reson Imaging 2021
23
21

Feasibility of using linearly polarized rotating birdcage transmitters and close-fitting receive arrays in MRI to reduce SAR in the vicinity of deep brain simulation implants.
Laleh Golestanirad, Boris Keil, Leonardo M Angelone, Giorgio Bonmassar, Azma Mareyam, Lawrence L Wald. Magn Reson Med 2017
40
10

RF safety of wires in interventional MRI: using a safety index.
Christopher J Yeung, Robert C Susil, Ergin Atalar. Magn Reson Med 2002
125
9

Magnetic resonance imaging and cochlear implants: compatibility and safety aspects.
C Teissl, C Kremser, E S Hochmair, I J Hochmair-Desoyer. J Magn Reson Imaging 1999
73
9


Neural stimulation and recording electrodes.
Stuart F Cogan. Annu Rev Biomed Eng 2008
881
9

Magnetic properties of materials for MR engineering, micro-MR and beyond.
Matthias C Wapler, Jochen Leupold, Iulius Dragonu, Dominik von Elverfeld, Maxim Zaitsev, Ulrike Wallrabe. J Magn Reson 2014
44
9

Measuring RF-induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leads.
Peter Nordbeck, Ingo Weiss, Philipp Ehses, Oliver Ritter, Marcus Warmuth, Florian Fidler, Volker Herold, Peter M Jakob, Mark E Ladd, Harald H Quick,[...]. Magn Reson Med 2009
102
9

Safety of localizing epilepsy monitoring intracranial electroencephalograph electrodes using MRI: radiofrequency-induced heating.
David W Carmichael, John S Thornton, Roman Rodionov, Rachel Thornton, Andrew McEvoy, Philip J Allen, Louis Lemieux. J Magn Reson Imaging 2008
54
9

Designing passive MRI-safe implantable conducting leads with electrodes.
Paul A Bottomley, Ananda Kumar, William A Edelstein, Justin M Allen, Parag V Karmarkar. Med Phys 2010
55
9

Feasibility of simultaneous intracranial EEG-fMRI in humans: a safety study.
David W Carmichael, John S Thornton, Roman Rodionov, Rachel Thornton, Andrew W McEvoy, Roger J Ordidge, Philip J Allen, Louis Lemieux. Neuroimage 2010
65
9

MR imaging-related heating of deep brain stimulation electrodes: in vitro study.
Daniel A Finelli, Ali R Rezai, Paul M Ruggieri, Jean A Tkach, John A Nyenhuis, Greg Hrdlicka, Ashwini Sharan, Jorge Gonzalez-Martinez, Paul H Stypulkowski, Frank G Shellock. AJNR Am J Neuroradiol 2002
91
9

Magnetic resonance imaging with cochlear implants and auditory brainstem implants: Are we truly practicing MRI safety?
Matthew Shew, Helena Wichova, James Lin, Luke N Ledbetter, Hinrich Staecker. Laryngoscope 2019
31
12

Calculation of MRI-induced heating of an implanted medical lead wire with an electric field transfer function.
Sung-Min Park, Rungkiet Kamondetdacha, John A Nyenhuis. J Magn Reson Imaging 2007
94
9

Realistic modeling of deep brain stimulation implants for electromagnetic MRI safety studies.
Bastien Guerin, Peter Serano, Maria Ida Iacono, Todd M Herrington, Alik S Widge, Darin D Dougherty, Giorgio Bonmassar, Leonardo M Angelone, Lawrence L Wald. Phys Med Biol 2018
17
23

Evaluation of the RF heating of a generic deep brain stimulator exposed in 1.5 T magnetic resonance scanners.
Eugenia Cabot, Tom Lloyd, Andreas Christ, Wolfgang Kainz, Mark Douglas, Gregg Stenzel, Steve Wedan, Niels Kuster. Bioelectromagnetics 2013
39
10

RF-induced heating in tissue near bilateral DBS implants during MRI at 1.5 T and 3T: The role of surgical lead management.
Laleh Golestanirad, John Kirsch, Giorgio Bonmassar, Sean Downs, Behzad Elahi, Alastair Martin, Maria-Ida Iacono, Leonardo M Angelone, Boris Keil, Lawrence L Wald,[...]. Neuroimage 2019
39
10

Measurements and simulation of RF heating of implanted stereo-electroencephalography electrodes during MR scans.
Bhumi Bhusal, Pallab Bhattacharyya, Tanvir Baig, Stephen Jones, Michael Martens. Magn Reson Med 2018
14
28

Graphene Encapsulated Copper Microwires as Highly MRI Compatible Neural Electrodes.
Siyuan Zhao, Xiaojun Liu, Zheng Xu, Huaying Ren, Bing Deng, Miao Tang, Linlin Lu, Xuefeng Fu, Hailin Peng, Zhongfan Liu,[...]. Nano Lett 2016
38
10

MR imaging of implanted depth and subdural electrodes: is it safe?
L M Davis, D D Spencer, S S Spencer, R A Bronen. Epilepsy Res 1999
37
10

Investigation of Parallel Radiofrequency Transmission for the Reduction of Heating in Long Conductive Leads in 3 Tesla Magnetic Resonance Imaging.
Clare E McElcheran, Benson Yang, Kevan J T Anderson, Laleh Golenstani-Rad, Simon J Graham. PLoS One 2015
31
9


Controlling radiofrequency-induced currents in guidewires using parallel transmit.
Maryam Etezadi-Amoli, Pascal Stang, Adam Kerr, John Pauly, Greig Scott. Magn Reson Med 2015
32
9

Reduction of implant RF heating through modification of transmit coil electric field.
Yigitcan Eryaman, Burak Akin, Ergin Atalar. Magn Reson Med 2011
56
6

Safely assessing radiofrequency heating potential of conductive devices using image-based current measurements.
Gregory H Griffin, Kevan J T Anderson, Haydar Celik, Graham A Wright. Magn Reson Med 2015
26
11

Parallel transmit pulse design for patients with deep brain stimulation implants.
Yigitcan Eryaman, Bastien Guerin, Can Akgun, Joaquin L Herraiz, Adrian Martin, Angel Torrado-Carvajal, Norberto Malpica, Juan A Hernandez-Tamames, Emanuele Schiavi, Elfar Adalsteinsson,[...]. Magn Reson Med 2015
41
7

3-Tesla MRI in patients with fully implanted deep brain stimulation devices: a preliminary study in 10 patients.
Francesco Sammartino, Vibhor Krishna, Tejas Sankar, Jason Fisico, Suneil K Kalia, Mojgan Hodaie, Walter Kucharczyk, David J Mikulis, Adrian Crawley, Andres M Lozano. J Neurosurg 2017
21
14


Magnetic resonance imaging in cochlear implant recipients: pros and cons.
Emanuel Kanal. JAMA Otolaryngol Head Neck Surg 2015
6
50

MRI without magnet removal in neurofibromatosis type 2 patients with cochlear and auditory brainstem implants.
Joanna Walton, Neil P Donnelly, Yu Chuen Tam, Ilse Joubert, Juliette Durie-Gair, Cay Jackson, Richard A Mannion, James R Tysome, Patrick R Axon, Daniel J Scoffings. Otol Neurotol 2014
61
6

Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study.
Franca Wagner, Wilhelm Wimmer, Lars Leidolt, Mattheus Vischer, Stefan Weder, Roland Wiest, Georgios Mantokoudis, Marco D Caversaccio. PLoS One 2015
29
10

Cochlear implants and magnetic resonance scans: A case report and review.
Stephen J Broomfield, Melville Da Cruz, William P R Gibson. Cochlear Implants Int 2013
23
13

Demagnetization of cochlear implants and temperature changes in 3.0T MRI environment.
Omid Majdani, Martin Leinung, Thomas Rau, Arash Akbarian, Martin Zimmerling, Minoo Lenarz, Thomas Lenarz, Robert Labadie. Otolaryngol Head Neck Surg 2008
50
6

Intracranial EEG-fMRI analysis of focal epileptiform discharges in humans.
Cameron B J Cunningham, Bradley G Goodyear, Radwa Badawy, Fateh Zaamout, Daniel J Pittman, Craig A Beers, Paolo Federico. Epilepsia 2012
33
9

Highly Stable Glassy Carbon Interfaces for Long-Term Neural Stimulation and Low-Noise Recording of Brain Activity.
Maria Vomero, Elisa Castagnola, Francesca Ciarpella, Emma Maggiolini, Noah Goshi, Elena Zucchini, Stefano Carli, Luciano Fadiga, Sam Kassegne, Davide Ricci. Sci Rep 2017
52
6


Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.