A citation-based method for searching scientific literature

R S Mazze, D Lucido, O Langer, K Hartmann, D Rodbard. Diabetes Care 1987
Times Cited: 86







List of co-cited articles
498 articles co-cited >1



Times Cited
  Times     Co-cited
Similarity


Characterizing glucose exposure for individuals with normal glucose tolerance using continuous glucose monitoring and ambulatory glucose profile analysis.
Roger S Mazze, Ellie Strock, David Wesley, Sarah Borgman, Blaine Morgan, Richard Bergenstal, Robert Cuddihy. Diabetes Technol Ther 2008
109
38

Recommendations for standardizing glucose reporting and analysis to optimize clinical decision making in diabetes: the Ambulatory Glucose Profile (AGP).
Richard M Bergenstal, Andrew J Ahmann, Timothy Bailey, Roy W Beck, Joan Bissen, Bruce Buckingham, Larry Deeb, Robert H Dolin, Satish K Garg, Robin Goland,[...]. Diabetes Technol Ther 2013
151
31

International Consensus on Use of Continuous Glucose Monitoring.
Thomas Danne, Revital Nimri, Tadej Battelino, Richard M Bergenstal, Kelly L Close, J Hans DeVries, Satish Garg, Lutz Heinemann, Irl Hirsch, Stephanie A Amiel,[...]. Diabetes Care 2017
617
24


Translating the A1C assay into estimated average glucose values.
David M Nathan, Judith Kuenen, Rikke Borg, Hui Zheng, David Schoenfeld, Robert J Heine. Diabetes Care 2008
896
19



CONTINUOUS GLUCOSE MONITORING: A CONSENSUS CONFERENCE OF THE AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS AND AMERICAN COLLEGE OF ENDOCRINOLOGY.
Vivian A Fonseca, George Grunberger, Henry Anhalt, Timothy S Bailey, Thomas Blevins, Satish K Garg, Yehuda Handelsman, Irl B Hirsch, Eric A Orzeck, Victor Lawrence Roberts,[...]. Endocr Pract 2016
105
17




Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections: The DIAMOND Randomized Clinical Trial.
Roy W Beck, Tonya Riddlesworth, Katrina Ruedy, Andrew Ahmann, Richard Bergenstal, Stacie Haller, Craig Kollman, Davida Kruger, Janet B McGill, William Polonsky,[...]. JAMA 2017
435
15

Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range.
Tadej Battelino, Thomas Danne, Richard M Bergenstal, Stephanie A Amiel, Roy Beck, Torben Biester, Emanuele Bosi, Bruce A Buckingham, William T Cefalu, Kelly L Close,[...]. Diabetes Care 2019
660
15


The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System.
Timothy Bailey, Bruce W Bode, Mark P Christiansen, Leslie J Klaff, Shridhara Alva. Diabetes Technol Ther 2015
313
13

Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial.
Jan Bolinder, Ramiro Antuna, Petronella Geelhoed-Duijvestijn, Jens Kröger, Raimund Weitgasser. Lancet 2016
387
13


Activation of oxidative stress by acute glucose fluctuations compared with sustained chronic hyperglycemia in patients with type 2 diabetes.
Louis Monnier, Emilie Mas, Christine Ginet, Françoise Michel, Laetitia Villon, Jean-Paul Cristol, Claude Colette. JAMA 2006
12

Rate of hypoglycemia in insulin-treated patients with type 2 diabetes can be predicted from glycemic variability data.
Yongming Qu, Scott J Jacober, Qianyi Zhang, Linda L Wolka, J Hans DeVries. Diabetes Technol Ther 2012
84
13

Recommendations for standardizing glucose reporting and analysis to optimize clinical decision making in diabetes: the ambulatory glucose profile.
Richard M Bergenstal, Andrew J Ahmann, Timothy Bailey, Roy W Beck, Joan Bissen, Bruce Buckingham, Larry Deeb, Robert H Dolin, Satish K Garg, Robin Goland,[...]. J Diabetes Sci Technol 2013
65
16


Glucose Management Indicator (GMI): A New Term for Estimating A1C From Continuous Glucose Monitoring.
Richard M Bergenstal, Roy W Beck, Kelly L Close, George Grunberger, David B Sacks, Aaron Kowalski, Adam S Brown, Lutz Heinemann, Grazia Aleppo, Donna B Ryan,[...]. Diabetes Care 2018
158
12


Evaluation of a new measure of blood glucose variability in diabetes.
Boris P Kovatchev, Erik Otto, Daniel Cox, Linda Gonder-Frederick, William Clarke. Diabetes Care 2006
217
11

A method for assessing quality of control from glucose profiles.
N R Hill, P C Hindmarsh, R J Stevens, I M Stratton, J C Levy, D R Matthews. Diabet Med 2007
85
11

The contribution of glucose variability to asymptomatic hypoglycemia in persons with type 2 diabetes.
Louis Monnier, Anne Wojtusciszyn, Claude Colette, David Owens. Diabetes Technol Ther 2011
109
11

Short- and long-term effects of real-time continuous glucose monitoring in patients with type 2 diabetes.
Robert A Vigersky, Stephanie J Fonda, Mary Chellappa, M Susan Walker, Nicole M Ehrhardt. Diabetes Care 2012
134
11

Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry.
Jenise C Wong, Nicole C Foster, David M Maahs, Dan Raghinaru, Richard M Bergenstal, Andrew J Ahmann, Anne L Peters, Bruce W Bode, Grazia Aleppo, Irl B Hirsch,[...]. Diabetes Care 2014
201
11

Toward Defining the Threshold Between Low and High Glucose Variability in Diabetes.
Louis Monnier, Claude Colette, Anne Wojtusciszyn, Sylvie Dejager, Eric Renard, Nicolas Molinari, David R Owens. Diabetes Care 2017
137
11

Validation of Time in Range as an Outcome Measure for Diabetes Clinical Trials.
Roy W Beck, Richard M Bergenstal, Tonya D Riddlesworth, Craig Kollman, Zhaomian Li, Adam S Brown, Kelly L Close. Diabetes Care 2019
209
11

Association of Time in Range, as Assessed by Continuous Glucose Monitoring, With Diabetic Retinopathy in Type 2 Diabetes.
Jingyi Lu, Xiaojing Ma, Jian Zhou, Lei Zhang, Yifei Mo, Lingwen Ying, Wei Lu, Wei Zhu, Yuqian Bao, Robert A Vigersky,[...]. Diabetes Care 2018
150
11

The Relationships Between Time in Range, Hyperglycemia Metrics, and HbA1c.
Roy W Beck, Richard M Bergenstal, Peiyao Cheng, Craig Kollman, Anders L Carlson, Mary L Johnson, David Rodbard. J Diabetes Sci Technol 2019
117
11

The significance of one abnormal glucose tolerance test value on adverse outcome in pregnancy.
O Langer, L Brustman, A Anyaegbunam, R Mazze. Am J Obstet Gynecol 1987
171
10

Reliability of blood glucose monitoring by patients with diabetes mellitus.
R S Mazze, H Shamoon, R Pasmantier, D Lucido, J Murphy, K Hartmann, V Kuykendall, W Lopatin. Am J Med 1984
219
10


Assessment of risk for severe hypoglycemia among adults with IDDM: validation of the low blood glucose index.
B P Kovatchev, D J Cox, L A Gonder-Frederick, D Young-Hyman, D Schlundt, W Clarke. Diabetes Care 1998
218
10

Oscillating glucose is more deleterious to endothelial function and oxidative stress than mean glucose in normal and type 2 diabetic patients.
Antonio Ceriello, Katherine Esposito, Ludovica Piconi, Michael A Ihnat, Jessica E Thorpe, Roberto Testa, Massimo Boemi, Dario Giugliano. Diabetes 2008
712
10

Continuous glucose monitoring and intensive treatment of type 1 diabetes.
William V Tamborlane, Roy W Beck, Bruce W Bode, Bruce Buckingham, H Peter Chase, Robert Clemons, Rosanna Fiallo-Scharer, Larry A Fox, Lisa K Gilliam, Irl B Hirsch,[...]. N Engl J Med 2008
940
10

Statistical tools to analyze continuous glucose monitor data.
William Clarke, Boris Kovatchev. Diabetes Technol Ther 2009
129
10

Diurnal glucose patterns of exenatide once weekly: a 1-year study using continuous glucose monitoring with ambulatory glucose profile analysis.
Roger Mazze, Ellie Strock, Blaine Morgan, David Wesley, Richard Bergenstal, Robert Cuddihy. Endocr Pract 2009
20
45

Role of continuous glucose monitoring for type 2 in diabetes management and research.
Robert Vigersky, Maneesh Shrivastav. J Diabetes Complications 2017
47
19

Clinical Use of Continuous Glucose Monitoring in Adults with Type 2 Diabetes.
Anders L Carlson, Deborah M Mullen, Richard M Bergenstal. Diabetes Technol Ther 2017
58
15

The Fallacy of Average: How Using HbA1c Alone to Assess Glycemic Control Can Be Misleading.
Roy W Beck, Crystal G Connor, Deborah M Mullen, David M Wesley, Richard M Bergenstal. Diabetes Care 2017
149
10

The Relationship of Hemoglobin A1C to Time-in-Range in Patients with Diabetes.
Robert A Vigersky, Chantal McMahon. Diabetes Technol Ther 2019
116
10


Improved quality of glycemic control and reduced glycemic variability with use of continuous glucose monitoring.
David Rodbard, Timothy Bailey, Lois Jovanovic, Howard Zisser, Roy Kaplan, Satish K Garg. Diabetes Technol Ther 2009
96
9



The effect of continuous glucose monitoring in well-controlled type 1 diabetes.
Roy W Beck, Irl B Hirsch, Lori Laffel, William V Tamborlane, Bruce W Bode, Bruce Buckingham, Peter Chase, Robert Clemons, Rosanna Fiallo-Scharer, Larry A Fox,[...]. Diabetes Care 2009
262
9



Co-cited is the co-citation frequency, indicating how many articles cite the article together with the query article. Similarity is the co-citation as percentage of the times cited of the query article or the article in the search results, whichever is the lowest. These numbers are calculated for the last 100 citations when articles are cited more than 100 times.